Asset ID: |
1-72-1312147.1 |
Update Date: | 2012-05-26 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1312147.1
:
VSM - FSC3931 VCF4 card failure on VSM5 causes cluster outage
Related Items |
- Sun StorageTek VSM System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
|
In this Document
Created from <SR 3-2871739681>
Applies to:
Sun StorageTek VSM System - Version 5 and later
IBM z/OS on System z
Symptoms
VCF4 card type in VSM5 or VSM5C fails with FSC3931 and results in a cluster outage.
Cause
The FSC3931 is a continuous channel interrupt (hot interrupt). This failure causes a series of FSC3931 check zeros and each check zero fences an IUP until all IUPs in the cluster have been fenced.
Solution
The solution to avoid the problem on the VSM5 is to upgrade to D02.12.08.00 or higher level of microcode. The solution to avoid the problem on the VSM5C is to upgrade to H02.12.08.00 or higher level of microcode.
If running a lower level of microcode and this problem is encountered then the recovery plan is to perform a cluster recovery or perform a disruptive recovery of the subsystem. Contact support for the current version of the cluster recovery procedure. During either recovery procedure the suspect VCF4 card should be replaced.
Attachments
This solution has no attachment