Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1305331.1
Update Date:2012-09-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  1305331.1 :   SL3000 - Robot Hung While Auditing Tapes With Device Response Timeouts  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • HP LTO3 Tape Drive
  •  
  • HP LTO4 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
HP LTO3 Tape Drive - Version Not Applicable and later
HP LTO4 Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.
Checked for relevance on 14-Sept-2012.

Symptoms

Robot Hung While Auditing Tapes With Device Response Timeouts.

Cause

Found site using dual barcode labels originally designed for HP library.
Dual Barcode labels are not supported.

Solution

The dual barcode LTO labels were intended for HP Galactica library's to handle LTO labeled tapes. These style of labels were originally designed to support DLT drives. HP discontinued support of these labels with LTO3 drives. HP only supports these labels on LTO1 and LTO2 cartridges.

The SL3000 released with LTO3/4 support and these style of labels have not been tested nor certified in the SL3000.

Refer to attached file for example of unsupported volser label.


Attachments
This solution has no attachment