Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1293137.1
Update Date:2012-07-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1293137.1 :   SL8500 - IP Switch Failure.. How to Diagnose  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential (PARTNER). Do not distribute to customers.
Reason: Confidential for Partners and Oracle Support personnel


Applies to:

Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

If the internal ethernet switch located behind the smoke detector should fail, diagnosis of the problem can be delayed due to the confusing symptoms.

Some of the symptoms are as follows:-
Library does not mount any tapes to drives, but may appear to stay connected to host.
You or the customer can log into your Remote SLC session using your laptop or networked customer PC. (Engineers would log into library port1A/2A/2B or SDP).
In the Remote SLConsole session (customer or PC), the drive folder is completely missing, I.e. there are no drives available.... (No IP access to HBT card)
Elevators, CAP’s and Pass Through Ports all offline, in red. (No IP access)
You are not able to log into the Local Operator Panel, on the front of the library. Error message similar to "Server not available" when you try to log in. (No IP access)
The library does not attempt to audit the drives after a library reboot.
No lights on 3com IP switch positioned top right of rear of library.

Red ICON denoting a device failure associated with the CAP, Elevators, and SSD (Service Safety Door)

Cause

The fault is likely to be the 3COM switch. PSU on switch has failed and the switch will have no LEDS illuminated.

Solution

Refer to the attached document for complete details on how to resolve this issue.


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback