![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1287213.1 : Sp:Fault.Security.Integrity-Compromised
In this Document
Created from <SR 3-2821383707> Applies to:Exadata Database Machine V2 - Version Not Applicable to Not Applicable [Release N/A]Oracle Exadata Storage Server Software - Version 11.2.1.2.0 to 11.2.2.2.0 [Release 11.2] Linux x86-64 SymptomsAfter Powering down an Exadata cell or compute node alerts are raised of log entries created like: ChangesChanging hardware components (e.g. flash cards) CauseIf the AC power is not removed from the chassis before replacing te components then the ILOM (which is not powered down by the front panel power switch) will detect the removal of the lid and flag an intrusion detection fault. SolutionThis message occurs when the chassis cover has been removed while AC is still attached to the chassis. Attachments This solution has no attachment |
||||||||||||||||||
|