![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1283914.1 : Troubleshooting Sun Storage[TM] Array Unknown Battery Status
In this Document
Applies to:Sun Storage 6140 Array - Version Not Applicable and laterSun Storage 6540 Array - Version Not Applicable and later Sun Storage 6130 Array - Version Not Applicable and later Sun Storage 2510 Array - Version Not Applicable and later Sun Storage 2540 Array - Version Not Applicable and later Information in this document applies to any platform. SymptomsCritical Faults of:
Reference: <Document: 1021057.1> Verify Sun StorageTek[TM] 2500 and Sun Storage[TM] 6000 Critical Faults via the User Interface To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Storage Disk 2000, 3000, 6000 RAID Arrays & JBODs Community
CauseA possible controller offline/failure has caused a problem in getting the battery status, or, possibly, a failure in the cache battery handling system of the array has lost track of the battery status. Solution 1. Verify the Critical Faults on the system and make sure that there is a critical fault for one or both batteries as follows.
If the faults are listed, continue to Step 2. <Document: 1392919.1> Troubleshooting Sun Storage[TM] Array non-SMART Battery Faults
you will need to resolve the controller issue prior to addressing the battery status.
The batteries for a 6130 array are not customer replaceable and require an Oracle Service person to replace or reseat.
You can remove and reseat these batteries without any impact to host data access. The write caching that the batteries protect has already been disabled by the fault(s) in the symptoms list. The battteries in these arrays are customer replaceable but also require that the controller be offlined and removed to access the battery. In order to do this on an active system, you must have a dual controller configuration and a multipathing environment configured to allow the IO access through the surviving controller. Single controller arrays (some 2510/2530/2540 models) require an outage as there is no redundant path.
Note: Follow carefully the instructions in Service Advisor, under Battery Removal and Replacement procedures. Depending on the model you may require a static mat and screwdriver to remove the battery, as is the case with any 2500 array. The 2500-M2 arrays also require an air blocker to be inserted in the vacated controller slot to properly cool the array while the controller is removed.
References<NOTE:1021054.1> - Troubleshooting Sun Storage[TM] Array SMART Battery Faults<NOTE:1021057.1> - How to verify Sun StorageTek[TM] 2500 and Sun Storage[TM] 6000 and J4000 Critical Faults via the User Interface <NOTE:1021066.1> - Verify Sun Storage[TM] Array Array Type via the User Interface <NOTE:1021113.1> - Sun Storage[TM] Arrays: Troubleshooting RAID Controller Failures <NOTE:1392919.1> - Troubleshooting Sun Storage[TM] Array non-SMART Battery Faults <NOTE:1398972.1> - Write Cache Disabled on Sun StorageTek 6540 Arrays After Losing One AC Power Input Attachments This solution has no attachment |
||||||||||||||||||
|