Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1268577.1
Update Date:2012-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1268577.1 :   LTO - LTO Tape Drive IPL Issue With SL-Series Tape Library  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL500 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Checked for relevance on 22-May-2012.

Symptoms

There is a timing issue with the LTO tape drive installed in a SL500/SL3000/SL8500 tape library when the drive is IPLed.

Changes

This issue was found while reseting the IP address on the HP LTO-5 tape drive.  When the IP Reset button on the back of the sled is pressed, the HP LTO-5 drive does an IPL.

Cause

The IPL takes less than 10 seconds, during this time the SL500 does not know the drive has been reset and does not reconnect the FC or SAS interface when the drive comes back online.

Solution

To reconnect the interface, the drive sled needs to be removed for at least 10 seconds.

Resetting the IP address on the IBM LTO-4 & LTO-5 and HP LTO-4 tape drives does not have the same effect; the drive is not IPLed during an IP Reset (only the Belisarius card (IBM) and Dione card (HP) are IPLed).  If the drives are IPLed via telnet or VOP, then they have the same issue.

The final fix will be in future release of code.

SL500 - Fixed after 14.09 code release.
SL3000 - Fixed in 3.0 code
SL8500 - Fixed in 7.0 code

@SCN # 22496