Solution Type  Problem Resolution Sure

Solution  1132935.1 :   VTL - Failover wizard fails reporting wrong number of targets and initiators  


Related Items
  • Sun StorageTek VTL Plus Storage Appliance
  •  
  • Sun StorageTek VTL Storage Appliance
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  




In this Document
  Symptoms
  Cause
  Solution


Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656   [Release: 1.0 to 2.0]
Sun StorageTek VTL Storage Appliance - Version: 4.0 - Build 1221 to 4.0 - Build 1221   [Release: 4.0 to 4.0]
Information in this document applies to any platform.
.
***Checked for relevance on 19-07-2011*** (dd-mm-yyyy)

Symptoms

  • Failover wizard reports 3 targets, but only 2 initiators (should be equal)
  • Failover wizard reports wrong number of targets and initiators

Cause

VTL Console may not register changes as if should.

Solution

1. A rescan sometimes clears the devices (even though the clients are zoned and OS can see them, the SAN clients are not defined to VTL, so VTL should not pick them up).

2. If rescan does not help, a reboot also sometimes clears the devices.

3. If reboot doesn't help, deactivate client host zoning, so VTL server cannot discover them, and rescan devices in VTL Console

4. If zoning changes are not possible, ipstor.conf file can be modified to remove the WWN of the discovered devices (VTL engineering should be engaged to perform this modification).

Attachments
This solution has no attachment