L180/700/1400 - Drives Dropping Out of Configuration or Not Recognizing Certain Drive Slots In Library
Related Items |
- Sun StorageTek L180 Tape Library
- Sun StorageTek L1400 Tape Library
- Sun StorageTek L700e Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
|
In this Document
Applies to:
Sun StorageTek L180 Tape Library - Version Not Applicable and later
Sun StorageTek L700e Tape Library - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek L1400 Tape Library - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Checked for relevance on 19-Dec-2011.
Symptoms
Drives dropping out of library configuration.
Certain drive slots not being recognized.
Lost library configuration information.
Library IPL is successful but drive drops out of configuration days later. IPL will bring drive back.
Problem remains with the drive tower slot after drive tray has been swapped with another drive.
Changes
Older libraries that have been installed for some time.
Cause
Contamination build up on drive tower connectors.
Solution
Drive towers have been replaced for this problem.
The following solution should be tried prior to drive tower replacement.
- Acquire a quality contact cleaner from a local electronics supply store.
- Spray the connector in the suspected drive tower slot.
- Push the drive in/out several times.
- Let the solution dry on the connector.
- Install the tape drive/tray assembly into the drive tower.
- Power up the library and tray assembly.
The drive should now show up in the library configuration.
This procedure has worked on several drive towers.