![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1022293.1 : T10000 - Drive SNO's With FSC013E, Due to Drive Failed to Get Keys, Drive Fails to Failover to Another KMA
PreviouslyPublishedAs 279531 Symptoms Drive SNO's with FSC013E Drive failed to get keys Drive fails to failover to another KMA KMA Audit log reports error: Register Agent KWK CoreSecurity RegisterAgentKWK failed Error 000287000281 Drive dump ECPT Trace: 837:AUDIT_CLIENT_AGENT_REGISTER_KWK_ERROR:172.18.18.113: TX_WAIT 2042 0dd2b9fe Log_function : SoapFaultCode=SOAP-ENV:Server SoapFaultString=Server Error SoapFaultDetail=Unknown::172.18.18.113 Resolution T10000 code RH.44.11x will fix the FSC013E issue. Looks like drive logic does not call it to failover to another KMA. Only really an issue if running KMS 2.1 or in FIPs mode, as then it will do software encryption if sca6000 fails. FSC013E is due to the Wait Queue backs up since the KMA does not respond and the lower level encryption code never returned to check the Wait Queue. Engineering is working on a change to empty the queue on timeouts, and to failover if error 837 is reported. Engineering is still working on fix so drive fails over if gets an 837:AUDIT_CLIENT_AGENT_REGISTER_KWK_ERROR error. Product Sun StorageTek Crypto Key Management Station 2.0 Sun StorageTek T10000 Tape Drive Sun StorageTek T10000B Tape Drive KMA 2.0 T10000 FSC013E Error 000287000281 Drive failed to get keys Product_uuid 08af52b0-9732-11de-9d26-080020a9ed93 | Sun StorageTek Crypto Key Management Station 2.0 30ce78cb-cfec-11da-a933-080020a9ed93 | Sun StorageTek T10000 Tape Drive f548dda5-2673-11dc-9482-080020a9ed93 | Sun StorageTek T10000B Tape Drive Attachments This solution has no attachment |
||||||||||||
|