Symptoms

Error messages generated when running acsss_config for a non-partitioned library:

(Note: This problem can also happen when running 'config acs new'. )
/export/home/ACSSS/config/in_lib_conf: Error response from library handler, LH_ERR_REQUEST_INVALID

/export/home/ACSSS/config/in_lib_conf: Cannot establish library communications

2150 E Cm_ProcessResponses.C 1  1155
Lh error: Cm_4400::ProcessAck: ACS 0 configured to ACSLS with partition ID = 0, but the library is NOT partitioned.

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
The host interface on the SL3000 library was set to non-partitioned SCSI and should be non-partitioned HLI (host LMU interface).



Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.