Solution Type  Problem Resolution Sure

Solution  1020245.1 :   L700/L180/HP LTO - Drives Do Not Display "Busy" on Library Op Panel When Reading/Writing to the Drive  


Related Items
  • HP LTO2 Tape Drive
  •  
  • HP LTO3 Tape Drive
  •  
  • Sun StorageTek L700e Tape Library
  •  
  • HP LTO4 Tape Drive
  •  
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  

PreviouslyPublishedAs
254808


Applies to:

Sun StorageTek L700 Tape Library - Version Not Applicable and later
Sun StorageTek L700e Tape Library - Version Not Applicable and later
HP LTO2 Tape Drive - Version Not Applicable and later
HP LTO3 Tape Drive - Version Not Applicable and later
HP LTO4 Tape Drive - Version Not Applicable and later
All Platforms
Checked for relevance on 25-July-2012.

Symptoms

HP LTO drives do not display "busy" on the Library Op Panel when reading or writing to the drive.


Changes

Firmware updated.

Cause

This bug was reported to have been fixed in 3.18.02 library code but due to a compiler malfunction, the SCN was not merged into the code.

Solution

L700 SPS code 3.18.31 has been created with the actual fix.   This fix will be integrated into the next level code release.

Contact Tape Hardware Support should you need the SPS code.  This is done by opening a ticket via MOS.