Asset ID: |
1-72-1019746.1 |
Update Date: | 2012-07-20 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1019746.1
:
Dismount Errors for T10KB Cleaning Media in SL3000 and SL8500
Related Items |
- Sun StorageTek SL3000 Modular Library System
- Sun StorageTek SL8500 Modular Library System
- Sun StorageTek Host Software Component (HSC) for MVS and z/OS
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Library Software>SN-TP: MAINSW HSC-MVS
- .Old GCS Categories>Sun Microsystems>Storage Software>Mainframe Software
|
PreviouslyPublishedAs
245048
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Sun StorageTek Host Software Component (HSC) for MVS and z/OS - Version 6.2 and later
IBM z/OS on System z
Checked for relevance on 7-Dec-2010.
Symptoms
Error messages are received for T10KB cleaning cartridge dismount
=SLS0923I DRIVE 880D HAS BEEN CLEANED USING CLN058
46 =SLS0107D DISMOUNT OF CLN058 FROM DRIVE 880D - DRIVE HAS LOADED
CARTRIDGE; REPLY DISMOUNT, RETRY, OR IGNORE (D/R/I)
R 46,D
IEE600I REPLY TO 46 IS;D
=SLS0662I LMU RESPONSE ERROR - 00,000,18,00
=SLS0698I REQ ACS 00 SEQ 02/550 REQ C DISMOUNT VOL CLN058 SRC 01/01:07:00 DRV 880D TGT 01/02:02:00 CEL
=SLS0699I RESPONSE ACS 00 SEQ 02/550 ERR 10/02 DRIVE IS NOT OPERATIONAL RET'D TO SRC LSM 01
*=SLS0117E DISMOUNT OF CLN058 FROM DRIVE 880D - LMU ERROR 65156515 ACS 00
=SLS0080I MOUNT OF INV240 ON DRIVE 880D - VOLUME AT 00:01:08:03:00
=SLS0662I LMU RESPONSE ERROR - 00,000,18,00
=SLS0698I REQ ACS 00 SEQ 02/551 REQ B MOUNT VOL INV240 SRC 01/08:03:00 CEL TGT 01/01:07:00 DRV 880D
=SLS0699I RESPONSE ACS 00 SEQ 02/551 ERR 04/05 DRIVE IS FULL RET'D TO SRC LSM 01
=SLS0130I DRIVE 880D FOUND FULL WHILE ATTEMPTING MOUNT OF INV240
*=SLS0867E ATTEMPTING TO LOCATE ERRANT VOLUME CLN058
=SLS0873I ERRANT RECOVERY OF CLN058 - VOLUME AT DRIVE 880D
*47 =SLS0869D ERRANT RECOVERY OF CLN058 - DRIVE 880D IS LOADED; REPLY RETRY, IGNORE, OR DISMOUNT (R/I/D)
Cause
For T10KB cleaning cartridges only, the library (SL3000 or SL8500) sends a Mount Response to HSC before the clean action has completed. This results in HSC attempting to dismount the cleaning cartridge before the cleaning cartridge has been unloaded.
Solution
Please open an SR using your hardware CSI and the serial number of one of the T10000 tape drive serial numbers. This will route the SR to the tape hardware team who will be able to assist.
Attachments
This solution has no attachment