![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1019590.1 : KMS - Upgrade of KMS Software Fails
PreviouslyPublishedAs 241806
Applies to:Sun StorageTek Crypto Key Management System - Version: Not ApplicableAll Platforms SymptomsUpgrading KMS version can fail to activate if the SCA6000 Mars Crypto card has failed.During the upgrade, the card BIOS gets updated. If the card has failed or not detected by Solaris OS, the code activate can not continue. Check KMSAuditEntries Log: If the below message is seen, this is an indication that the SCA6000 card has failed. Change Software Version - Update firmware failed, cannot continue software activation - Error 000154000258 Changes{CHANGE}Cause{CAUSE}SolutionResolutionIf SCA6000 Crypto card has failed or is not detected by Solaris, then the KMA will need to be replaced. The SCA6000 card is not a FRU. FRU's for the KMS are found at: Attachments This solution has no attachment |
||||||||||||
|