Solution Type  Problem Resolution Sure

Solution  1019263.1 :   VTL - Not all usable space available  


Related Items
  • Sun StorageTek VTL Prime System
  •  
  • Sun StorageTek VTL Plus Storage Appliance
  •  
  • Sun StorageTek VTL Storage Appliance
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
237924


Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0
Sun StorageTek VTL Prime System - Version: 1.0 - Build 1813 to 1.1 - Build 2076   [Release: 1.0 to 1.0]
Sun StorageTek VTL Storage Appliance - Version: 4.0 - Build 1221 to 4.0 - Build 1221   [Release: 4.0 to 4.0]
All Platforms
.
***Checked for relevance on 28-06-2011*** (dd-mm-yyyy)

Symptoms

VTL is not allowing all available space to be used
Not all usable space available
It is believed that 160TB storage should be available on a VTL with 170TB raw, customer sees ~120TB.

Cause

Actual usable space is approximately 25-30% less than the available raw storage.

Solution

Actual usable space is approximately 25-30% less than the available raw storage
This is expected.  For example, with 170TB raw and 160TB usable disk array storage,  
VTL only shows 120TB. R5 parity, hot spares, and the fact that disk manufacturers
round up on disk size to 500GB reduces available storage by 30%. Engineering provided
the 30% estimate and it is very close to what the customer sees.




Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.