Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1019051.1
Update Date:2011-12-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1019051.1 :   SL8500 - Pass Thru Port Initialization Failures  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  

PreviouslyPublishedAs
233801


Applies to:

Sun StorageTek SL8500 Modular Library System
All Platforms
Checked for relevance on 6-Dec-2011.

Symptoms

If the PTP is not able to trip both sensors during initialization, the PTP module will not come ready.
5017
RC5017
Result code

Cause

In a limited number of cases it has been due to an improperly adjusted sensor.


The failure mode can be seen in the error log with an error similar to “ptp,

/usr/local/bin/Ptpif, error, 0000, 5017, "Director - initResponse()

cmo_init_ptp(): SRV Init PTP failed; cmo_init_recover_ptp(): Gate Unknown -

Slide Path/Sensor Check Failed; Sweep Slide Failed; End of Text"”.


Refer to the attached file to show the sensor location.

Solution

Resolution
To resolve the issue, remove the PTP assembly, and adjust the sensors so that when the PTP is extended the sensor is tripped on the side the array is extended towards. The sensors can be found on the underside of the PTP assembly.







Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.