![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1018383.1 : L20/L40/L80/L180/L700 - Service Required Light On - Library Fails to Initialize
PreviouslyPublishedAs 229895
Applies to:Sun StorageTek L700e Tape Library - Version: Not ApplicableSun StorageTek L80 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L180 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L20 Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 24-Jan-2012. SymptomsService required light is onInitialization failed Initialization failed message from library panel Blank screen after pressing MENU button Changes{CHANGE}Cause{CAUSE}SolutionResolutionUse the following steps to resolve problem: 1. Check the FSC logs to help determine the error 2. Check location of hand assembly for possible robotics Initialization problem 3. Attempt to re-IPL the library with a Power ON Reset 4. Check cable connections to MPC and MPB 5. Replace MPC or MPB as required Attachments This solution has no attachment |
||||||||||||
|