Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1017225.1
Update Date:2012-08-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1017225.1 :   SL8500 - CAP Will Not Come Online  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  

PreviouslyPublishedAs
228123


Applies to:

Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
All Platforms
Checked for relevance on 6-Aug-2012.


Symptoms

CAP will not come online
CAP does not work
CAP broken

Changes

{CHANGE}

Cause

Defective switch on cable.

Solution

Resolution
Replace cable PN 314810702, CBL ASSY,HBZ-CAP.

Verified that the wires are swapped at P790.  At the end of the cable that plugs in just below the HBZ card, it is the small plug that has four pins.  Two wires are the commons, Black, and the other two are purple. They are the wires from the cap switch. After tracing out the wires and comparing to another SL8500, it appears the wires are swapped at P790 where the cable that runs from the CAPs through the floor of the Customer Interface module and plug in just below the HBZ card. If the CAP A closed switch is plugged into the jack for CAP B, the CAP would come online and work.




Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.