Asset ID: |
1-72-1016754.1 |
Update Date: | 2012-06-04 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1016754.1
:
VSM/SVA - FSC79A5 - pfaelg4a.dat overflow due to High Volume of FSC3FFA errors
Related Items |
- Sun StorageTek VSM System
- Sun StorageTek V2X SVA Disk System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
- .Old GCS Categories>Sun Microsystems>Storage - Disk>Datacenter Disk - Other
|
PreviouslyPublishedAs
226923
Applies to:
Sun StorageTek V2X SVA Disk System - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
All Platforms
Updated for currency 05/20/11
Symptoms
The PFAELG4A.DAT error log overflows is due to a high quantity of FSC3FFA errors on V2X and V2Xf.
Cause
The FSC3FFA entries in the PFAELG4A.CNT or PFAELG4B.CNT file are not errors - they are events and are not a problem.
Definition of FSC:
#define FSC3FFA_EST_PPRC_PAIR_NO_COPY_SUCCESSFUL 0x3FFA
CSE: @SAME
ENG: A PSF Establish PPRC Pair order that specified
'no copy' was received and completed successfully.
Solution
Resolution
To eliminate overflow:
1. VSM/SVA HW support needs to review PFAELG4A.CNT and PFAELG4B.CNT files to verify no indication of a problem.
Note: Specifically check for errors when pfaelg4a.dat file exceeded 5 MB and was renamed pfaelg4b.dat.
2. If entries are just informational, no action is required other than verify V2X, V2Xf or VSM box is at latest code levels.
Attachments
This solution has no attachment