![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1016507.1 : VSM - z/OS Host Messages IOS000I / IOS071I / SLS6698I
PreviouslyPublishedAs 226341
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0IBM z/OS on System z SymptomsThe following z/OS host informational messages may be issued during periods of high VTD (virtual tape drive) activity on the VTSS or other circumstances:IOS071I xxxx,xx,SLS0, MISSING CHANNEL AND DEVICE END IOS000I xxxx,**,SIM,**,**06,,**,S3=GTA,SLS0 IOS071I xxxx,**,xxxxxxxx, START PENDING SLS6698I ECAM I/O error on VTD xxxx Note: SLS messages are issued by VTCS software. ChangesVerify the MIH, missing interrupt handler, is set to 20:00 minutes or more. Issue this host system command:D IOS MIH, DEV=(xxxx) If this MIH setting is 20:00 or more, then investigate further. CauseOne explanation related to the VSM could be:During a timeframe of high VTD (virtual tape drive) activity, one or more LPARs may not receive adequate services if another LPAR is prioritized and creates a heavy workload on the VTSS. SolutionIf the cause is determined to be due to high VTD activity during a specific timeframe, then a system administrator may decide to reschedule peak workloads to the VTSS.Further investigation may be warranted for VTCS SLSxxxxx ECAM messages or hardware. Note: Multiple missing channel end messages on a specific tape drive or RTD (real tape drive) with various tapes may indicate a tape drive hardware problem. Attachments This solution has no attachment |
||||||||||||
|