![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1016322.1 : VSM - Fails to Initialize during HSC/VTCS start-up after SLS6675E with RC=08
PreviouslyPublishedAs 225794
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0All Platforms SymptomsVTSS fails to initialize during HSC/VTCS start-upMessage SLS6675E occurs for one or more VTDs Lack of SLS6632I "VTSS server ready" message for each VTSS SLS6632I does not occur if only one VTSS is configured Message SLS6670E may also be issued SLS6675E VTSS:nnnnnnnn VTD:dddd CONFIGURATION ERROR RC=6A40FF0C SLS6675E VTSS: nnnnnnnn VTD: dddd CONFIGURATION ERROR RC=00000008 SUBSYSTEM INFO: 99999999/mmmm/ooooooo SLS6698I ECAM I/O ERROR ON VTD dddd SLS6670E RTD rrrrrrrr FAILED INITIAL CONFIGURATION WITH CC=254 RC=0 CauseThis problem generally occurs with a new install of a VTSS when the production arrays within the VTSS itself were not configured.SolutionThe FSE needs to configure the production arrays within the VTSS subsystem. After that has been completed, then stop and restart HSC/VTCS.Previously Published As STKKB75767 Attachments This solution has no attachment |
||||||||||||
|