Asset ID: |
1-72-1014443.1 |
Update Date: | 2012-07-30 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1014443.1
:
L700/180/1400 - FSC3203 - Hand Failed to Initialize
Related Items |
- Sun StorageTek L700 Tape Library
- Sun StorageTek L180 Tape Library
- Sun StorageTek L1400 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
- .Old GCS Categories>Sun Microsystems>Storage - Tape>Libraries - L-Series
|
PreviouslyPublishedAs
221248
Applies to:
Sun StorageTek L180 Tape Library
Sun StorageTek L700 Tape Library
Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later]
All Platforms
Checked for relevance on 2-Feb-2011.
Symptoms
FSC3203
Hand fails to initialize
Changes
{CHANGE}
Cause
FSC3203
ERR_CMO_FAILED_HAND_INIT, Hand failed initialization.
FRU: LOCATION: CONFIDENCE %:
HAND ASSY LSM 85
Z flex cable LSM 10
MPC LCU 5
SEVERITY - error
Solution
ResolutionFollow These steps to resolve or diagnose the problem
- Open the library and check the hand for any obstructions. Clear path or remove any tapes stuck between drives and the hand or in the hand it's self.
- Manually check the range of the hand by moving it up and down and left to right gently. Do not force it, but rather ensure that it has motion without sticking, skipping or grinding.
- IPL the library and see if it comes back to a normal state, if so, watch the library for several days and ensure that it does not happen repeatedly.
- If it happens repeatedly or the above does not resolve, Gather further FSC's, Code levels and continue diagnosis.
@ L700, L180
Previously Published As STKKB38902
Attachments
This solution has no attachment