Solution Type Problem Resolution Sure Solution 1014137.1 : VSM - SLS6684I Ecam Error CC=09 RC=30
PreviouslyPublishedAs 220457
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0All Platforms Reviewed for relevancy on 06-15-2011 SymptomsSLS6684I RTD ON VTSS RETURNED ECAM ERROR CC=9 RC=30Example of error customer will see: SLS6659I VTSS VTSSC11 SIM:00001000060000F90E00008D8200001042000E690000FFFE00004CC000000000 SLS6684I RTD RTD9D31 ON VTSS VTSSC11 RETURNED ECAM ERROR CC=9 RC=30 CauseOperation was interrupted due to a cache reinitialize operation.SolutionContact Oracle and have an SR created and routed to VSM support so files can be downloadedfor diagnosis 1. Download full set of base files. 2. Review files and determine marginal cache card. 3. Page case out to local support to replace cache card. Previously Published As STKKB71837 Attachments This solution has no attachment |
||||||||||||
|