Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1014137.1
Update Date:2011-06-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1014137.1 :   VSM - SLS6684I Ecam Error CC=09 RC=30  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  

PreviouslyPublishedAs
220457


Applies to:

Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0
All Platforms
Reviewed for relevancy on 06-15-2011

Symptoms

SLS6684I RTD ON VTSS RETURNED ECAM ERROR CC=9 RC=30


Example of error customer will see:
SLS6659I VTSS VTSSC11 SIM:00001000060000F90E00008D8200001042000E690000FFFE00004CC000000000
SLS6684I RTD RTD9D31 ON VTSS VTSSC11 RETURNED ECAM ERROR CC=9 RC=30

Cause

Operation was interrupted due to a cache reinitialize operation.

Solution

Contact Oracle and have an SR created and routed to VSM support so files can be downloaded
for diagnosis



1. Download full set of base files.
2. Review files and determine marginal cache card.
3. Page case out to local support to replace cache card.






Previously Published As
STKKB71837

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback