Solution Type Problem Resolution Sure Solution 1014045.1 : L1400/L700/L180 - Library will not mount tape into drive
PreviouslyPublishedAs 220257 Applies to:Sun StorageTek L700 Tape Library - Version Not Applicable and laterSun StorageTek L1400 Tape Library - Version Not Applicable and later Sun StorageTek L180 Tape Library - Version Not Applicable and later All Platforms Checked for relevance on 26-July-2012. SymptomsArm is not moving, stays in front of drive Changes{CHANGE} CauseFSC3E1D: Drive detected Media error. FRU's = cart, 79%; drive 20%; logical error 1%. SolutionResolution
2. Inspect cartridge for any damage. If it is damaged remove cartridge from the library. 3. If cartridge seems to be okay, test by mounting tape on another drive. If problem persists remove cartridge from the library. 4. Test mounting on drive with known good cartridge. Replace drive if this fails.