Solution Type  Problem Resolution Sure

Solution  1013859.1 :   L1400/L700/L180 - FSC3208 - Hand Put Failures  


Related Items
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  

PreviouslyPublishedAs
219853


Applies to:

Sun StorageTek L180 Tape Library - Version Not Applicable and later
Sun StorageTek L700 Tape Library - Version Not Applicable and later
Sun StorageTek L1400 Tape Library - Version Not Applicable and later
All Platforms
Checked for relevance on 26-July-2012.


Symptoms

FSC3208
Library reporting PUT failures

Changes

{CHANGE}

Cause

FSC:3208
ERR_CMO_HAND_EMPTY_ON_PUT,
Cannot Put the cartridge, the hand is empty.
FRU: LOCATION: CONFIDENCE %:
HAND ASSY LSM 90
MPC LSM 10

Solution

Resolution
Take the following steps to resolve problem:

1. Check for possible stuck tape in drive or cell array.
2. Clean fingers.
3. Run Get/Put Diagnostics on library in attempt to duplicate problem.
4. If problem continues, replace the hand assembly.