Solution Type Problem Resolution Sure Solution 1013678.1 : T10000 - Drives Connected to Windows 2003 SP1 Disappear in Heavy Use
PreviouslyPublishedAs 219306 Applies to:Sun StorageTek T10000A Tape Drive - Version Not Applicable and laterSun StorageTek T10000B Tape Drive - Version Not Applicable and later All Platforms Checked for relevance on 30-July-2012. SymptomsTape drives disappear from the server after a period of heavy use. Changes{CHANGE} CauseDown level device driver. SolutionChange HBA driver: The tape drives disappear from the server after a period of heavy use. The drives are connected directly to the server. They are not going through a switch. The customer is using Emlux LP11002 4gb HBAs at firmware level 250A6 and driver level 1.20A7, which is the next to the latest version for both the firmware and drivers. Customer changed the HBA drivers from the Storport driver to the FC port driver. This appears to have resolved the problem.