Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1013678.1
Update Date:2012-07-30
Keywords:

Solution Type  Problem Resolution Sure

Solution  1013678.1 :   T10000 - Drives Connected to Windows 2003 SP1 Disappear in Heavy Use  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  

PreviouslyPublishedAs
219306


Applies to:

Sun StorageTek T10000A Tape Drive - Version Not Applicable and later
Sun StorageTek T10000B Tape Drive - Version Not Applicable and later
All Platforms
Checked for relevance on 30-July-2012.

Symptoms

Tape drives disappear from the server after a period of heavy use.
Drive goes away.

Changes

{CHANGE}

Cause

Down level device driver.

Solution

Change HBA driver:
Customer have T10000 drives connected to a server running Windows 2003 SP1.

The tape drives disappear from the server after a period of heavy use. The drives are connected directly to the server. They are not going through a switch.

The customer is using Emlux LP11002 4gb HBAs at firmware level 250A6 and driver level 1.20A7, which is the next to the latest version for both the firmware and drivers.

Customer changed the HBA drivers from the Storport driver to the FC port driver. This appears to have resolved the problem.