![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1013632.1 : VTL - Cannot configure more than 4 target ports on VTL server with 8 available ports
PreviouslyPublishedAs 219208
Applies to:Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0Sun StorageTek VTL Prime System - Version: 1.0 - Build 1813 to 1.1 - Build 2076 [Release: 1.0 to 1.0] Sun StorageTek VTL Value System - Version: 1.0 - Build 1323 and later [Release: 1.0 and later] Sun StorageTek VTL Storage Appliance - Version: 4.0 - Build 1221 and later [Release: 4.0 and later] Information in this document applies to any platform. . ***Checked for relevance on 10-08-2011*** (dd-mm-yyyy) SymptomsCannot configure more than 4 target ports on VTL server.ChangesAfter "Enabling Target Mode" on 4 ports, option to enable is grayed out on all other ports.CauseThis is a license limitation.SolutionAnother license for an additional 4 target ports (they come in sets of four) will need to be ordered. Please contact Oracle Sales representative to get new license keys ordered.References<NOTE:1343023.1> - VTL - How to obtain a license key codeAttachments This solution has no attachment |
||||||||||||
|