Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1013632.1
Update Date:2011-08-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  1013632.1 :   VTL - Cannot configure more than 4 target ports on VTL server with 8 available ports  


Related Items
  • Sun StorageTek VTL Prime System
  •  
  • Sun StorageTek VTL Storage Appliance
  •  
  • Sun StorageTek VTL Plus Storage Appliance
  •  
  • Sun StorageTek VTL Value System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
219208


Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0
Sun StorageTek VTL Prime System - Version: 1.0 - Build 1813 to 1.1 - Build 2076   [Release: 1.0 to 1.0]
Sun StorageTek VTL Value System - Version: 1.0 - Build 1323 and later    [Release: 1.0 and later]
Sun StorageTek VTL Storage Appliance - Version: 4.0 - Build 1221 and later    [Release: 4.0 and later]
Information in this document applies to any platform.
.
***Checked for relevance on 10-08-2011*** (dd-mm-yyyy)

Symptoms

Cannot configure more than 4 target ports on VTL server.

Changes

After "Enabling Target Mode" on 4 ports, option to enable is grayed out on all other ports.

Cause

This is a license limitation.

Solution

Another license for an additional 4 target ports (they come in sets of four) will need to be ordered. Please contact Oracle Sales representative to get new license keys ordered.

References

<NOTE:1343023.1> - VTL - How to obtain a license key code

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.