![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1013454.1 : SL8500 - HBot Inoperative Due to HBB Card failure - FB102113 Fixes ESD Problem with 9840
PreviouslyPublishedAs 218843 Applies to:Sun StorageTek 9840D Tape Drive - Version Not Applicable and laterSun StorageTek 9840B Tape Drive - Version Not Applicable and later Sun StorageTek 9840 Tape Drive - Version Not Applicable and later Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later All Platforms Checked for relevance on 22-May-2012. SymptomsLibrary stops working Changes{CHANGE} CauseUnder lower humidity conditions (below 35%) with 9840x drives in an SL8500, an ESD event can occur. CR1602 on the HBB card has suffered failures due to electrostatic discharge resulting from 9840X cartridge static buildup. The discharge, coupled onto the input power lines of the card, exceeds the voltage rating of CR1602 (60 volt part). The system or product is not operational resulting in a critical impact to the customer's business requiring immediate resolution. SolutionResolution The solution is to replace the present MBRS360 CR1602 with a 1SMC48ATS 48 volt zener transient protection diode. This new part is specifically designed to absorb transients created by electrostatic discharges. The cards remain equivalent. Part Numbers current for this EC are: 313913804 ROBOT FRU ASSY 313926502 HBZ MODULE FRU ASSY 313960803 MECHANISM FRU ASSY,SL85PT