Solution Type Problem Resolution Sure Solution 1013441.1 : SL8500 - CAP Locking Intermittent Error with Result Code 7009
PreviouslyPublishedAs 218809 Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterAll Platforms Checked for relevance on 14-Sept-2012. SymptomsResult Code 7009
Changes{CHANGE} CauseAs the CAP is rotating to the close position it can stop short approximately .5"; the unlock led stays illuminated on the front panel and the Sbot will not audit the CAP. The S-bots will not audit the CAP until the library controller can verify the CAP is in the lock position. This can occur because the latching pin hits the latch at an incorrect angle. SolutionFix:
Note: Be sure to order the field Bill to get parts and instructions. Pages 2-5 of FB102197 have detailed instructions and photos.