Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1013408.1
Update Date:2012-10-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  1013408.1 :   SL500 - Inoperative Drive Does Not Report Empty or Full Status Correctly  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  

PreviouslyPublishedAs
218736


Applies to:

Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
All Platforms
Checked for relevance on 8-Oct-2012.

Symptoms

False drive status being reported.
If a drive is taken to an inoperative state, the full or empty status from the drive is not correct.
Library status of drive is incorrect.

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
This problem is in 1409 SL500 library code.

 

Use the "Cartridge Print" CLI command to determine if a cartridge is present in the drive or not. If a cartridge is present, it must be manually removed from the drive.


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.