![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1012107.1 : Sun Fire[TM] V1280/Netra[TM] 1280: "I2c error:Slave did not ACK" Message
PreviouslyPublishedAs 216662 Applies to:Sun Fire V1280 Server - Version All Versions and laterAll Platforms SymptomsThe message, "I2c error: slave did not ACK" is displayed when using Firmware 5.13.0014 during the screset operation on v1280/netra1280. CauseA timing firmware bug <SunBug 5053287> Solution
This message does not effect platform operation. This issue will be resolved in Firmware Release 5.17.3, 5.18.0 and all higher releases. It is strongly suggested to install the most current firmware. See 1342226.1 for how to obtain and install the most current firmware.
POST Complete.
Attachments This solution has no attachment |
||||||||||||
|