![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1009829.1 : Sun Fire[TM] T2000 hangs during boot.
PreviouslyPublishedAs 213486
Applies to:Sun Fire T2000 Server - Version: Not ApplicableAll Platforms SymptomsWhen booting or rebooting a Sun Fire[TM] T2000 the boot process hangs at "checking ufs volumes" but before "/dev/... logging" messages. Machine was fine until modem was attached to the serial port (ttya). Machine is running Solaris[TM]10 11/06.CauseT2000 is running Solaris[TM]10 11/06. SolutionResolutionThe following should help address: Problem only appears with those T2000's running Solaris[TM]10 11/06 (S10_u3). Installing Patch ID :120011-14 or later will fix the problem. Relief/Workaround Remove modem or serial device from serial port prior to booting/rebootin then re-attach after machine has fully booted. Attachments This solution has no attachment |
||||||||||||
|