Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1009267.1
Update Date:2012-07-30
Keywords:

Solution Type  Problem Resolution Sure

Solution  1009267.1 :   cfgadm: Component system is busy, try again  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
212826


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server
Sun Fire E25K Server
All Platforms

Symptoms

On Solaris[TM] 9 04/04, cfgadm on PCI slot fails with "cfgadm: Component system is busy, try again" error messages.

# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
IO0 HPCI connected configured ok
IO0::pci0 io connected configured ok
IO0::pci1 io connected configured ok
IO0::pci2 io connected configured ok
IO0::pci3 io connected configured ok
IO1 HPCI connected configured ok
IO1::pci0 io connected configured ok
IO1::pci1 io connected configured ok
IO1::pci2 io connected configured ok
IO1::pci3 io connected configured ok
IO16 HPCI connected configured ok
IO16::pci0 io connected configured ok
IO16::pci1 io connected configured ok
IO16::pci2 io connected configured ok
IO16::pci3 io connected configured ok
SB0 CPU disconnected unconfigured unknown
SB9 CPU connected configured ok
SB9::cpu0 cpu connected configured ok
SB9::cpu1 cpu connected configured ok
SB9::cpu2 cpu connected configured ok
SB9::memory memory connected configured ok
SB10 CPU connected configured ok
SB10::cpu2 cpu connected configured ok
SB10::cpu3 cpu connected configured ok
SB10::memory memory connected configured ok
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t0d0 disk connected configured unknown
c1::dsk/c1t1d0 disk connected configured unknown
c2 scsi-bus connected configured unknown
c2::dsk/c2t0d0 disk connected configured unknown
c2::dsk/c2t1d0 disk connected configured unknown
pcisch0:e00b1slot1 pci-pci/hp connected configured ok
pcisch1:e00b1slot0 ethernet/hp connected configured ok
pcisch2:e00b1slot3 pci-pci/hp connected configured ok
pcisch3:e00b1slot2 ethernet/hp connected configured ok
pcisch4:e16b1slot1 unknown connected unconfigured unknown
pcisch5:e16b1slot0 unknown connected unconfigured unknown
pcisch6:e16b1slot3 pci-pci/hp connected configured ok
pcisch7:e16b1slot2 unknown connected unconfigured unknown
pcisch8:e01b1slot3 pci-pci/hp connected configured ok
pcisch9:e01b1slot2 unknown connected unconfigured unknown
pcisch10:e01b1slot1 ethernet/hp connected configured ok
pcisch11:e01b1slot0 unknown connected unconfigured unknown
#
# cfgadm -c unconfigure pcisch1:e00b1slot0
cfgadm: Component system is busy, try again

Cause

Missing patch; install patch 116669-15 or newer to fix the issue.

Note: Solaris 9 is now EOL, please consider upgrading to a current Solaris release. Please check Oracle Lifetime Support Policy Documentation here for further references.

Solution

Resolution
Install Solaris 9 patch 116669-15 or newer (most recent release is Patch 116669-40: SunOS 5.9: md patch).

Relief/Workaround
Use the rcfgadm -c unconfigure PCI Slot instead of the cfgadm.

Doing rcfgadm on the same slot runs succefully.

v4u-15ka-sc1:sms-svc:24> rcfgadm -d A
Ap_Id                          Type         Receptacle   Occupant     Condition
IO0                            HPCI         connected    configured   ok
IO1                            HPCI         connected    configured   ok
IO16                           HPCI         connected    configured   ok
SB0                            CPU          disconnected unconfigured unknown
SB9                            CPU          connected    configured   ok
SB10                           CPU          connected    configured   ok
c0                             scsi-bus     connected    configured   unknown
c1                             scsi-bus     connected    configured   unknown
c2                             scsi-bus     connected    configured   unknown
pcisch0:e00b1slot1             pci-pci/hp   connected    configured   ok
pcisch1:e00b1slot0             ethernet/hp  connected    configured   ok
pcisch2:e00b1slot3             pci-pci/hp   connected    configured   ok
pcisch3:e00b1slot2             ethernet/hp  connected    configured   ok
pcisch4:e16b1slot1             unknown      connected    unconfigured unknown
pcisch5:e16b1slot0             unknown      connected    unconfigured unknown
pcisch6:e16b1slot3             pci-pci/hp   connected    configured   ok
pcisch7:e16b1slot2             unknown      connected    unconfigured unknown
pcisch8:e01b1slot3             pci-pci/hp   connected    configured   ok
pcisch9:e01b1slot2             unknown      connected    unconfigured unknown
pcisch10:e01b1slot1            ethernet/hp  connected    configured   ok
pcisch11:e01b1slot0            unknown      connected    unconfigured unknown


It is seen that once rcfgadm command completes successfully, cfgadm command from domain on the same slot starts working.
# cfgadm -al
 Ap_Id                          Type         Receptacle   Occupant     Condition
 IO0                            HPCI         connected    configured   ok
 IO0::pci0                      io           connected    configured   ok
 IO0::pci1                      io           connected    configured   ok
 IO0::pci2                      io           connected    configured   ok
 IO0::pci3                      io           connected    configured   ok
 [...]
 c0                             scsi-bus     connected    configured   unknown
 c0::dsk/c0t0d0                 disk         connected    configured   unknown
 c0::dsk/c0t1d0                 disk         connected    configured   unknown
 c1                             scsi-bus     connected    configured   unknown
 c1::dsk/c1t0d0                 disk         connected    configured   unknown
 c1::dsk/c1t1d0                 disk         connected    configured   unknown
 c2                             scsi-bus     connected    configured   unknown
 c2::dsk/c2t0d0                 disk         connected    configured   unknown
 c2::dsk/c2t1d0                 disk         connected    configured   unknown
 pcisch0:e00b1slot1             pci-pci/hp   connected    configured   ok
 pcisch1:e00b1slot0             ethernet/hp  connected    configured   ok
 pcisch2:e00b1slot3             pci-pci/hp   connected    configured   ok
 pcisch3:e00b1slot2             ethernet/hp  connected    configured   ok
 [...]
 pcisch11:e01b1slot0            unknown      connected    unconfigured unknown
 # cfgadm -c unconfigure pcisch1:e00b1slot0
 # cfgadm -al
 Ap_Id                          Type         Receptacle   Occupant     Condition
 IO0                            HPCI         connected    configured   ok
 IO0::pci0                      io           connected    configured   ok
 IO0::pci1                      io           connected    configured   ok
 IO0::pci2                      io           connected    configured   ok
 IO0::pci3                      io           connected    configured   ok
 [...]
 c0                             scsi-bus     connected    configured   unknown
 c0::dsk/c0t0d0                 disk         connected    configured   unknown
 c0::dsk/c0t1d0                 disk         connected    configured   unknown
 c1                             scsi-bus     connected    configured   unknown
 c1::dsk/c1t0d0                 disk         connected    configured   unknown
 c1::dsk/c1t1d0                 disk         connected    configured   unknown
 c2                             scsi-bus     connected    configured   unknown
 c2::dsk/c2t0d0                 disk         connected    configured   unknown
 c2::dsk/c2t1d0                 disk         connected    configured   unknown
 pcisch0:e00b1slot1             pci-pci/hp   connected    configured   ok
 pcisch1:e00b1slot0             unknown      connected    unconfigured unknown
 pcisch2:e00b1slot3             pci-pci/hp   connected    configured   ok
 pcisch3:e00b1slot2             ethernet/hp  connected    configured   ok
 [...]
 pcisch11:e01b1slot0            unknown      connected    unconfigured unknown
 #

Additional Information
For more information regarding this issue, see also: Change Request 5087647 and 5089083

Product
Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 15K Server
Sun Fire 12K Server

Keywords: busy, 12k, 15k, 20k, 25k, cfgadm


Previously Published As 77726



Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.