Solution Type  Problem Resolution Sure

Solution  1009079.1 :   Sun Fire[TM] V60x/V65x Servers: Temperature Sensor on the Server Gives a False Reading  


Related Items
  • Sun Fire V60x Server
  •  
  • Sun Fire V65x Server
  •  
Related Categories
  • PLA-Support>Sun Systems>x64>Server>SN-x64: SERVER 32bit
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>x64 Servers
  •  

PreviouslyPublishedAs
212526


Applies to:

Sun Fire V60x Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire V65x Server - Version: Not Applicable and later    [Release: N/A and later]
All Platforms

Symptoms

Symptoms

The temperature sensor on the server is giving an error that the temperature is too low, but the reading is false.

Cause

Cause

A temperature sensor calibration error existed in older BIOS releases.

Solution

Resolution

Check the BIOS version on the server; it might need to be updated. The BIOS updates can be found at the following location:
   http://www.oracle.com/technetwork/systems/patches/firmware/release-history-jsp-138416.html

If the current BIOS version is older than updates on the page, updates will need to be applied in sequential order until you arrive at the latest release.