Solution  1008914.1 :   Sun Fire[TM] 15K: Console stuck in IOSRAM mode  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
212263


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server
Sun Fire E25K Server
All Platforms

Symptoms

Sun Fire[TM] 15K: Console stuck in IOSRAM mode

Cause

Console cannot be toggled from IOSRAM to network: this may happen if no MAN network is configured at domain side.
~= Toggle the communication path between the network and IOSRAM interfaces.
The console was stuck in IOSRAM mode. On typing ~ IOSRAM mode is shown following ~= which should have toggled it.

Solution

Process for enabling dman interface

An /etc/ hostname.dman0 file is required for each domain. If the file is not configured, Solaris[TM] does not plumb the domain side I1 interface, thus it cannot switch to network.

Create the hostname.dman0 file, and then plumb and bring up the interface.

Example:

# vi /etc/hostname.dman0
192.168.100.2 netmask + broadcast + private up

Create a file for each domain. You can get the IP address from the /etc/opt/SUNWSMS/config/MAN.cf file.



Additional Information
How to enable the toggling of the console while the domain is in Single User mode with Solaris 10
In order to have the ~= work properly the following services should also be enabled:

    # svcadm enable svc:/system/filesystem/local:default
    # svcadm enable svc:/network/initial:default
    # svcadm enable svc:/platform/sun4u/sckmd:default

If the services are not enabled the following error will result
Sep 10 11:39:30 2008 v4u-15ka-sc1-gmp02 dxs[2092]-C(): [4953 69289009971095 NOTICE ConsoleCvcd.cc 270] Failed to switch domain console to network mode, due to KMD errors; sckmd may not be running on the domain.