Solution Type  Problem Resolution Sure

Solution  1006302.1 :   Sun Fire[TM] 12K/15K/E20K/E25K: Domain not Booting: "Domain failed by hpost: ecode=36"  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
208841


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire E25K Server - Version: Not Applicable and later    [Release: N/A and later]
All Platforms

Symptoms

The domain is not booting and displays the following message at the end of
the POST output:

Exitcode = 36: Non-configuration special hpost mode successful
POST (level=32, verbose=40) execution time 6:27
[5304] Domain failed by hpost: ecode=36
Resetting and deconfiguring: CPU at SB16
Resetting and deconfiguring: HPCI at IO16
Resetting and deconfiguring: EXB at EX16

Changes

When running hPOST to check a single SB, a new domain is created and two
flags are added to the .postrc file:

no_ioadapt_ok <= only SB will be tested
no_obp_handoff <= control won't be sent to OBP after finishing POST


Cause

When you later attempt to boot the domain, these flags set in the .postrc file will cause the boot to fail. The keyswitch mode reverts to "standby".

Solution

The solution is to remove both lines from the .postrc file.

Additional Information
.postrc example
================

/etc/opt/SUNWSMS/SMS1.3/config/R/.postrc:
verbose 40
err_print 64
level 32
no_ioadapt_ok
no_obp_handoff


Product
Sun Fire 15K Server
Sun Fire 12K Server

Internal Comments
This solution is intended for use by Sun IT and Sun IT Partner Engineers only.

Document: 1007568.1 contains the procedure to test a single slot 0 board w/o any IO
f15k, sms, 1.3, boot, no_ioadapt_ok, no_obp_handoff, ecode=36, setkeyswitch, standby