![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1006217.1 : Sun Fire[TM] System Controller: Warning Message Appears After the CP1500 Board Replacement
PreviouslyPublishedAs 208701 Applies to:Sun Fire 15K Server - Version Not Applicable and laterSun Fire 12K Server - Version Not Applicable and later All Platforms SymptomsThe following is the Sun Fire[TM] 15K System Controller warning message that appears after a CP1500 board replacement: CauseThe new SC doesn't have the proper firmware loaded. SolutionThe resolution is to do the following "flashupdate": root@sc0 # su - sms-svc sc0:sms-svc:1> cd /opt/SUNWSMS/firmware sc0:sms-svc:2> ls SCOBPimg.di nSSCPOST.di oSSCPOST.di sc0:sms-svc:3> flashupdate -f SCOBPimg.di sc0/fp0 Unable to determine local SC number. Only the local System Control Fproms can be updated. Do you wish to continue? (yes/no)? yes Current System Controller FPROM Information =========================================== ERROR: Invalid FPROM segment at offset 0. SC Flash Image Information ========================== Name: SSCOBP-dropins, Version: 1.3 Size: 144, Check Sum: 55375 Date Flashed: 03/09/04 Date Created: 03/09/04 Do you wish to update the SC User FPROM (yes/no)? yes Update SC at Local SC, FPROM 0 : Erasing... Done. Writing and verifying ... Done. sc0:sms-svc:4> ls SCOBPimg.di nSSCPOST.di oSSCPOST.di sc0:sms-svc:5> flashupdate -f nSSCPOST.di sc0/fp1 Unable to determine local SC number. Only the local System Control Fproms can be updated. Do you wish to continue? (yes/no)? yes Current SC FPROM Information ============================ ERROR: Invalid FPROM segment at offset 0. SC Flash Image Information ========================== Name: ExtPOST, Version: 1.24 Size: 210841, Check Sum: 44924 Date Flashed: 03/09/04 Date Created: 03/09/04 Do you wish to update the SC User FPROM (yes/no)? yes Update SC at Local SC, FPROM 1 : Erasing... Done. Writing and verifying ... Done. sc0:sms-svc:6> exit Reboot the System Controller and verify.
Reviewed for currency on 7/27/12 References<NOTE:1000816.1> - FAB: Standard: Reactive: Firmware upgrade required when replacing the CP1500 CPU on the System Controller of a Sun Fire 15K system.<NOTE:1001900.1> - Sun Fire[TM] 12K/15K: Checking and Updating SC Firmware(FW) Guidelines @<NOTE:1010734.1> - SunFire[TM] 12K/15K/E20K/E25K servers: Installing/Replacing a CP2140 (Othello+) in a SunFire 12K/15K/20K/25K server Attachments This solution has no attachment |
||||||||||||
|