Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1006217.1
Update Date:2012-07-30
Keywords:

Solution Type  Problem Resolution Sure

Solution  1006217.1 :   Sun Fire[TM] System Controller: Warning Message Appears After the CP1500 Board Replacement  


Related Items
  • Sun Fire 15K Server
  •  
  • Sun Fire 12K Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
208701


Applies to:

Sun Fire 15K Server - Version Not Applicable and later
Sun Fire 12K Server - Version Not Applicable and later
All Platforms

Symptoms

The following is the Sun Fire[TM] 15K System Controller warning message that appears after a CP1500 board replacement:

May 20 12:30:48 sc0 root: Warning: Unable to detect gchip in system configuration. The S99sms command should only be executed on a Sun Fire 15K System Controller.

Cause

The new SC doesn't have the proper firmware loaded.

Solution

The resolution is to do the following "flashupdate":

root@sc0 # su - sms-svc
sc0:sms-svc:1> cd /opt/SUNWSMS/firmware
sc0:sms-svc:2> ls
SCOBPimg.di  nSSCPOST.di  oSSCPOST.di
sc0:sms-svc:3> flashupdate -f SCOBPimg.di sc0/fp0
Unable to determine local SC number.
Only the local System Control Fproms can be updated.
Do you wish to continue? (yes/no)? yes
Current System Controller FPROM Information
===========================================
ERROR: Invalid FPROM segment at offset 0.
SC Flash Image Information
==========================
Name: SSCOBP-dropins, Version: 1.3
Size: 144, Check Sum: 55375
Date Flashed: 03/09/04
Date Created: 03/09/04
Do you wish to update the SC User FPROM (yes/no)? yes
Update SC at Local SC, FPROM 0 :
Erasing...
Done.
Writing and verifying ...
Done.

sc0:sms-svc:4> ls
SCOBPimg.di  nSSCPOST.di  oSSCPOST.di
sc0:sms-svc:5> flashupdate -f nSSCPOST.di sc0/fp1
Unable to determine local SC number.
Only the local System Control Fproms can be updated.
Do you wish to continue? (yes/no)? yes
Current SC FPROM Information
============================
ERROR: Invalid FPROM segment at offset 0.
SC Flash Image Information
==========================
Name: ExtPOST, Version: 1.24
Size: 210841, Check Sum: 44924
Date Flashed: 03/09/04
Date Created: 03/09/04
Do you wish to update the SC User FPROM (yes/no)? yes
Update SC at Local SC, FPROM 1 :
Erasing...
Done.
Writing and verifying ...
Done.
sc0:sms-svc:6> exit
Reboot the System Controller and verify.


Internal Comments
This procedure has been performed successfully on a customer's site.

Reviewed for currency on 7/27/12

References

<NOTE:1000816.1> - FAB: Standard: Reactive: Firmware upgrade required when replacing the CP1500 CPU on the System Controller of a Sun Fire 15K system.