Solution Type Problem Resolution Sure Solution 1005225.1 : Sun Fire[TM] V490 will not pass POST with a specific FC card configuration
PreviouslyPublishedAs 207320
Applies to:Sun Fire V490 ServerAll Platforms SymptomsThe Sun Fire[TM] V490 may not pass POST successfully when there are fiber cards (375-3102) in pci (Peripheral Component Interconnect) slot 0 AND slot 1. The error message that is displayed is "DATA ACCESS ERROR".ChangesThis problem is not seen when the cards are installed into any other pci slots.This problem is only seen using the cards 375-3102 that do not have a version number associated with them AND a bar code label with the QLA2310 designation. CauseFirmware interaction issue.SolutionWith OBP at 4.15.6 the error appears as: 0:0>Memory Block....Done With OBP at 4.18.6 the format of the error changes slightly:
Enabling system bus....... Done