![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1004770.1 : Sun Enterprise[TM] 10000: Error: can't communicate with DR daemon
PreviouslyPublishedAs 206622 Applies to:Sun Enterprise 10000 Server - Version Not Applicable and laterAll Platforms SymptomsWhen trying to attach or detach a System Board, you can get the following messages: Checking environment... CausePossible misconfiguration of inetd.conf. SolutionNowadays, security is a serious issue. Sometimes, when trying to protect our systems, we can disable some features that are needed for correct operation of the system. If you see the above errors, check the /etc/inetd.conf file for the domain. The DR line should be: 300326/4 tli rpc/tcp wait root /usr/platform/sun4u1/sbin/dr_daemon dr_daemon If the line is commented or missing from /etc/inetd.conf, you will not be able to use DR in that system. To solve the problem, perform the following as root user:
Product Internal section Previously Published As 71550 Attachments This solution has no attachment |
||||||||||||
|