![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1003308.1 : Sun Fire[TM]12K/15K/E20K/E25K: esmd warning; A power failure has been detected on a redundant power supply at ...
PreviouslyPublishedAs 204588 Applies to:Sun Fire 12K Server - Version Not Applicable to Not Applicable [Release N/A]Sun Fire 15K Server - Version Not Applicable to Not Applicable [Release N/A] Sun Fire E20K Server - Version Not Applicable to Not Applicable [Release N/A] Sun Fire E25K Server - Version Not Applicable to Not Applicable [Release N/A] All Platforms SymptomsThe following error messages appear in the system controller platform messages file ($SMSLOGGER/platform/messages): Mar 10 11:33:57 2002 orlocn01-sc0 esmd[506]: [2000 171363006794824 ERRSysControl.cc 1371] A power failure has been detected on a redundant power supply at ps1_power_good_l, located on CSB at CS1. SCHEDULE REPLACEMENT of CSB at CS1 as soon as possible. The same failure can be reported on an Expander Board. esmd[...]: [2000 4153696025929986 ERR SysControl.cc 1581] A power failure has been detected on a redundant power supply at ps0_power_good_l; located on EXB at EX7. SCHEDULE REPLACEMENT of EXB at EX7 as soon as possible. or esmd[...]: [0 8353244896562214 ERR SysControl.cc 1579] A failure has been detected on redundant PS at ps1_power_good_l; located on EXB at EX6. SCHEDULE REPLACEMENT of EXB at EX6 as soon as possible to restore redundancy. In case this problem occurrs on a IO Board the message will be: esmd[....]: [2000 3006117574587 ERR SysControl.cc 2772] A failure has been detected on redundant PS at +1.0-2.55_vdc0_ok; located on HPCI+ at IO17. SCHEDULE REPLACEMENT of HPCI+ at IO17 as soon as possible to restore redundancy. CauseExpander Boards, Centerplane Support Boards and IO Boards have 2 redundant power supplies, reported in the previous messages as ps0_power_good_l and ps1_power_good_l. Esmd tells you which one is the failing one and the action that needs to be taken. SolutionIn the case of the power supply warning message, it prescribes the course of action you should take ASAP. In this case, "schedule replacement of CSB at CS1 as soon as possible." or "schedule replacement of EXB at EX7 as soon as possible". esmd[...]: [0 47269795990296515 NOTICE SysControl.cc 5296]
poweron[...]: [6121 1491355281854766 ERR L2PowerControl.cc 325]
Product Attachments This solution has no attachment |
||||||||||||
|