![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type FAB (standard) Sure Solution 1495353.1 : SPARC Enterprise M8000/M9000 servers ACS three-phase Star connections may be reversed resulting in system hardware damage.
Sun FAB > Standard > Reactive In this Document
Oracle Confidential (PARTNER). Do not distribute to customers. Applies to:Sun SPARC Enterprise M9000-64 Server - Version Not Applicable to Not Applicable [Release N/A]Sun SPARC Enterprise M9000-32 Server - Version Not Applicable to Not Applicable [Release N/A] Sun SPARC Enterprise M8000 Server - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. __________ Part Number Description 371-2389 - AC Power Section D, Three Phase Star(ACSTPH_D), Fujitsu P/N CA06624-D313 371-2386 - AC Power Section B, Three Phase Star(ACSTPH_B): Fujitsu P/N CA06624-D113 SymptomsSPARC Enterprise M8000/M9000 servers with three-phase Star (aka Wye or Y) AC power may contain ACSTPH units which do not match "SPARC Enterprise M8000/M9000 Servers Site Planning Guide" (PN E23589-02) and "SPARC Enterprise M8000/M9000 Servers Installation Guide" (PN E27052) connection diagrams. Impact CauseA circuit protector used within the ACSTPH_B and ACSTPH_D became obsolete. The selected new part required reversed orientation of the three-phase power connection terminals. Systems began shipping as of August 13, 2012 via Deviation# D0001376 with this reversed wiring. SolutionWorkaround Oracle is working with the supplier to update this documentation, however it is not currently known when this activity will be completed. The original ACSTPH_D and ACSTPH_B contained three-phase power connection terminals in this orientation: L1, L2, L3, N. Identification of Affected Parts (how to) Servers with affected ACSTPH_B or ACSTPH_D units may be identified with either a red (interim notification) or yellow (final version) WARNING label. The red label indicates; WARNING: AC wiring configuration/sequence may not match what is indicated in the "SPARC Enterprise M8000/M9000 Servers Site Planning Guide" PN E23589-02 and "SPARC Enterprise M8000/M9000 Servers Installation Guide" PN E27052. - Reference the attached red warning label photo. The yellow label indicates; WARNING Ensure power wires match terminal labeling. L1, L2, L3, N *OR* N, L3, L2 ,L1 are possible terminal sequences - Reference the attached yellow warning label figure. No photo available. References Deviation: D0001376 For information about FAB documents, its release processes, implementation strategies and billing information, click here.
Attachments This solution has no attachment |
||||||||||||||||
|