Asset ID: |
1-73-1438477.1 |
Update Date: | 2012-03-26 |
Keywords: | |
Solution Type
FAB (standard) Sure
Solution
1438477.1
:
SATA DVD not seen via OBP or Solaris until server powercycled.
Related Items |
- Sun Netra T5440 Server
- Sun Netra T5220 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun FAB
|
In this Document
Symptoms
Changes
Cause
Solution
References
Oracle Confidential (PARTNER). Do not distribute to customers
Reason: FABs available to Internals and Partners only
Applies to:
Sun Netra T5440 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Sun Netra T5220 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A]
Information in this document applies to any platform.
__________
SUNBUG 7117136
Affected Parts:
371-4571 - Power Distribution Board, SATA
371-4568 - Power Distribution Board, SATA
Symptoms
This problem occurs during mkisofs and is identified via the reservation failed message below:
=============================
Looking for CD/DVD devices...
Looking for CD devices...
Node Connected Device Device type
----------------------+--------------------------------+-----------------
/dev/rdsk/c0t0d0s2 | TEAC DV-W28SS-R 1.0C | CD Reader/Writer
01:09:43
Checking for media...
Device : TEAC DV-W28SS-R Firmware : Rev. 1.0C () Media is blank
01:09:43
executing /usr/bin/mkisofs -r -J -V BKFULLSYS_1 -o /tmp/.iso/iso.img /tmp/.tar
01:12:42
INFO: vold is not running, a cd/dvd checksum verification can be performed.
01:15:00
Start cdwrite of /tmp/.tar, iso_space=/tmp/.iso.
Please wait...
Looking for CD devices...
Initializing device...done.
Preparing to write DVD
Setting reservation failed
Failed to create the DVD, hit <enter> to retry OR type "abort" to quit:
01:21:28
Checking for media...
Failed to create the DVD, hit <enter>
=============================
At this point, the dvd drive still shows under iostat -En and cfgadm still shows the dvd drive is connected but the cdrw -l and cdrw -M command does not show the drive. Following a reboot, the iostat and cfgadm also loses visibility to the drive.
Impact
This problem causes the SATA DVD to not be seen via Solaris or the OBP so is not useable until the entire system is power cycled.
Changes
Contributing Factors
This occurs on Netra systems with the gen 1 TEAC SATA DVD 390-0443 using vendor certified media.
PATA DVD drives are not impacted by this issue, which is what shipped in the T5520 prior to September of 2009, and in the T5440 prior to November of 2009.
Cause
Root CauseThe DVD drive has an internal connection to the USB bus. The USB driver will disconnect a device if there is no longer any communication between the device and the driver, or if it sees many resets or NACKs on the bus. The Oxford/PLX USB device never resets, so it cannot answer the polls from the USB driver - so there never appears to be a device on the bus. The state the device enters can only be corrected by a power cycle.
Solution
Workaround
The system should be power cycled (power disconnected) for 15 seconds which will make the DVD accessible again.
Resolution
The new Oxford firmware, oxford_v10.zip resolves this problem on Power Distribution Boards (PDB), 371-4571 (Netra T5220) and 371-4568 (Netra T5440).
This firmware can be obtained by Oracle employees from the internal Netra T5220 Patches/Firmware page. External document 1359374.1 provides an example of firmware installation, and can be found at;
https://support.us.oracle.com/oip/faces/secure/km/DocumentDisplay.jspx?id=1359374.1
Identification of Affected Parts (how to)
Document 1359374.1 indicates if the loaded firmware on PDB, 371-4571 (Netra T5220) and 371-4568 (Netra T5440) is the corrected version. The utility found in oxford_v10.zip is the only method verify this firmware's version.
Comments
New Netra T5220 PDB, 7026156 contains the new firmware, but either requires firmware 7.2.11.a or 7.4.2.a (or newer) or a workaround due to SUNBUG 7117136. However the preferred method to correct this is to perform the firmware upgrade.
References
BugID: 7050587, 7056939
Related URL(s): https://support.us.oracle.com/oip/faces/secure/km/DocumentDisplay.jspx?id=1359374.1
SRs: 3-3691911104, 3-3095993321, 3-3095993341
For information about FAB documents, its release processes, implementation strategies and billing information, click here.
In addition to the above you may email:
[email protected]
Contacts:
Contributor: [email protected]
Responsible Engineer: [email protected], [email protected]
Responsible Manager: [email protected]
Business Unit Group: Systems Group-Netra Systems and Networking
References
FAB > Standard > Reactive
Attachments
This solution has no attachment