Asset ID: |
1-73-1278026.1 |
Update Date: | 2012-09-25 |
Keywords: | |
Solution Type
FAB (standard) Sure
Solution
1278026.1
:
ST9990V and ST9985V USPV/VM DKS2F-K450FC HDDs have higher exposure to dual HDD failures with down-level DKU Code and Hitachi Dynamic Provisioning (HDP) on the same machine.
Related Items |
- Sun Storage 9990V System
- Sun Storage 9985V System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun FAB
- .Old GCS Categories>Sun Microsystems>Sun FAB>Standard>Reactive
|
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers.
Reason: FABs available to Internals and Partners only
Applies to:
Sun Storage 9985V System - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 9990V System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
__________
Affected Parts:
371-3059 - 72GB Disk Drive/15kmin-1
371-3060 - 146GB Disk Drive/15kmin-1
371-3637 - 300GB Disk Drive/15kmin-1
371-3061 - 300GB Disk Drive/10kmin-1
371-4206 - 400GB Disk Drive/10kmin-1
371-4474 - 450GB Disk Drive/15Kmin-1
371-4867 - 600GB Disk Drive/15Kmin Drive
Symptoms
Several instances of down-level DKS2F-K450FC HDDs experiencing high failure rates which lead to dual HDD failures in the same parity group.
Down-level firmware for DKS2F-K450FC HDDs can lead to dual HDD failures in the same parity group. This can lead to loss of data for the parity group and in the worst case if the parity group is part of an HDP pool, it could lead to loss of the entire pool.
Reference HDS Alert# 64803 for more information.
Impact:
Elevated disk drive failure rates can increase the chances of a dual drive failure within the same parity group. Because of this potential issue, please have service personnel upgrade the disk microcode as soon as possible.
This can lead to loss of data for the parity group and in the worst case, if the parity group is part of an HDP pool, it could lead to loss of the entire pool.
Disk model DKS2F-K450FC have seen higher failure rate than other disk models when disk microcode is lower than the above recommended code level.
To prevent this, it is critical that the firmware is upgraded as soon as possible. Note that we have not experienced this issue on other HDDs or the DKS2F-K450FC model HDD with updated DKU code.
Changes
Contributing Factors:
This problem may occur when all the following conditions below are met:
1. The system listed in the products section above are being used.
2. All current versions of microcode less than the fixed versions where
the disk drives installed have not had their firmware upgraded.
All R600 FC Disk drives with the following model prefixes could be affected;
DKS2E-K, DKS2F-K, DKS2G-K, DKS2E-J
Note: SATA drives and SSDs are not affected.
There has been several instances of down-level DKS2F-K450FC HDDs experiencing high failure rates which lead to dual HDD failures in the same parity group.
Using Hitachi Dynamic Provisioning (HDP) on the same machine with a larger number of DKS2F-K450FC HDDs increases potential for this failure. Therefore, if any of the HDP pools on these machines are made up of these down-level HDDs, there is the potential to lose the HDP pool.
Machines that have a larger percentage of DKS2F-K450HDDs are more at risk than those that have only a few of these drives.
If you need to set priorities, please target the machines on this list that are using HDP followed by those not using HDP.
Reference the attached for a matrix of affected code and code which incorporates the fix.
Cause
Root Cause:
Engineering has discovered a problem with a firmware change made to above mentioned disk drive models that are installable on the above mentioned R600 Hitachi Data Systems Storage Models.
Solution
Workaround
No workaround available - see Resolution section below.
Resolution
To prevent this, it is critical that the firmware is upgraded as soon as possible.
The recommended corrective action is to upgrade the microcode. Below is the MC with the fix incorporated.
60-07-56-00/00-M198 (or higher)
The enhancements in this microcode can eliminate 70 percent of the time it takes to recover a DP pool that has experienced a dual HDD failure. The enhanced microcode eliminated a number of previously required recovery steps, greatly improving the time required to restore a DP pool. We therefore consider it mandatory that all USPV&VM machines running Dynamic Provisioning should minimally run this microcode level.
To find a list of remotely connect systems, and the priority to upgrade please reference this list of systems.
http://gl-highend.us.oracle.com/eng/tech_docs/fab/DKU_Upgrade/DKU_Upgrade_CustList.xls
Comments
Subscribe to ST9900 up-to-date Alerts by referring the below link;
http://sejsc.us.oracle.com/alerts_via_alias.html
For ST9900 Maintenance Manuals go to;
http://pts-storage.us.oracle.com/products/T99x0/documentation.html
References:
Related URL(s):
HDS Alert -
http://gl-highend.us.oracle.com/eng/tech_docs/fab/DKU_Upgrade/Alert_065418-2.pdf
How to Identify minimum DKU Code Level Doc -
http://gl-highend.us.oracle.com/eng/tech_docs/fab/DKU_Upgrade/FAB_IdentifyDKUCode_66539.pdf
For information about FAB documents, its release processes, implementation strategies and billing information, click here.
In addition to the above you may email:
[email protected]
Contacts
Contributor: [email protected]
Responsible Engineer: [email protected]
Responsible Manager: [email protected]
Business Unit Group: NWS (Storage)
Attachments
This solution has no attachment