Solution Type  FAB (standard) Sure

Solution  1000705.1 :   Hitrack versions (prior to B.2) for the SE9990 and SE9985 arrays can exit unexpectedly and may not send SIM notifications.  


Related Items
  • Sun Storage 9990 System
  •  
  • Sun Storage 9985 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun FAB
  •  
  • .Old GCS Categories>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
200923


Product
Sun StorageTek 9990 System
Sun StorageTek 9985 System


Impact

Earlier versions of HiTrack for the SE9990 and SE9985 contained a bug that could cause the application to exit while performing file creation during the phone home process. This would lead to the subsystem not phoning home SIMs or daily calls. The Hitrack application will not restart automatically and must be manually restarted to once again begin receiving phone home and SIM data from the subsystem. This is an intermittent issue and might not occur on every phone home attempt.


Resolution

To remedy these issues, all SE9990 and SE9985 arrays should be running HiTrack version B.2 or higher. The latest version of HiTrack and the related ECN can be found on the SE9990.eng website at:

http://se9990.eng/ecn.html#HI-TRACK-ECN


Related Information
  • Manual: Maintenance Manuals for the 99xx series arrays
  • URL: http://pts-storage.us.oracle.com/products/T99x0/documentation.html

    Previously Published As: 102018

    Internal Contributor/submitter: [email protected] [Jeffrey Hibser]
    Internal Eng Business Unit Group: KE Authors
    Internal Eng Responsible Engineer: [email protected] [Jeffrey Hibser]
    Internal Services Knowledge Engineer: [email protected]

    Internal Kasp FAB Legacy ID: 102018

    Internal Sun Alert & FAB Admin Info
    Critical Category:
    Significant Change Date:
    Avoidance: Service Procedure
    Responsible Manager: null
    Original Admin Info: null

    Internal SA-FAB Eng Submission
    Hitrack versions (prior to B.2) for the SE9990 and SE9985 arrays can exit unexpectedly and may not send SIM notifications.

    Product_uuid
    15644879-f179-11d8-ab63-080020a9ed93|Sun StorageTek 9990 System
    73084edc-dc32-11d9-8a74-080020a9ed93|Sun StorageTek 9985 System