Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-73-1000662.1
Update Date:2012-09-25
Keywords:

Solution Type  FAB (standard) Sure

Solution  1000662.1 :   Process for handling unapproved or counterfeit DIMMs.  


Related Items
  • Sun Memory Module
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun FAB
  •  
  • .Old GCS Categories>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
200873


Product
Sun Fire 12K Server
Sun Blade 2000 Workstation
Sun Fire E20K Server
Sun Fire 280R Server
Sun Fire V880 Server
Netra 20 Server
Sun Fire 3800 Server
Sun Fire 4800 Server
Sun Fire 4810 Server
Sun Fire 6800 Server
Sun Fire 15K Server
Sun Blade 1000 Workstation
Sun Fire E6900 Server
Sun Fire V490 Server
Sun Fire E2900 Server
Sun Fire V1280 Server
Sun Fire V480 Server
Sun Fire E4900 Server
Sun Fire E25K Server
Netra 1280 Server
Sun Netra X4450 Server
Sun Netra X4250 Server
Sun Netra T5440 Server
Netra CP3260
Netra T5220 Server
Sun SPARC Enterprise T5440 Server
Sun SPARC Enterprise T5120 Server
Sun SPARC Enterprise T5220 Server
Sun SPARC Enterprise T5140 Server
Sun SPARC Enterprise T5240 Server
Sun SPARC Enterprise T6340 Server
Sun Blade T6320 Server Module
Sun Blade T6340 Server Module
Sun Netra T6340 Server Module
Sun Fire X4440 Server

Affected Part Numbers
501-6109 - 1GB DIMM
501-7386 - 1GB DIMM
501-6242 - 2GB NGDIMM

Impact

Process for handling unapproved or counterfeit DIMMs (see details below).

Contributing Factors

Not applicable.

Symptoms

There has been several incidents of customers attempting to use unapproved
DIMMs in Sun/Oracle systems.  While in some instances these DIMMs don't
cause any problems, in others they have been known to cause system failures.
Under no condition should service be provided to handle such DIMMs. 

Here is a list of known unapproved/counterfeit DIMMs:

The 501-6109-03 and 501-7386-03 1GB DIMM part numbers are not valid part numbers.

Although they might load into Sun/Oracle systems, they must not be installed by Oracle Service
Personnel or Partners in the Sun Fire E20K, E25K, F12K, F15K, 3800, 4800, 4810, 6800, E2900,
E4900, E6900, V1280, Netra 1280, Netra 20, Sun Blade 1000, 2000, Sun Fire 280R, V480, V490,
V880 and V890 systems.

In addition to the above part numbers, 2GB NGDIMM part number 501-6242 with SPD rev 1.14 is
also invalid. This part has a label on the DIMM that states the vendor is "Samsung" but the prtfru
shows the following:

    Date   = Mon Nov  5 05:29:30 MET 2001
    Vendor = Micron Technology

Sample photos of part number with SPD rev 1.14 are attached to this document.

DIMMs with Micron Module Serial Number D22F72C8 are unapproved DIMMs.
This is a repeated manufacturing serial number and does not have a
programmed Sun part number.

   /SPD_FBDIMM_R/SPD_Module_Serial_Number: D22F72C8

Additional clue:

   o The DIMMs do not have the the Sun_SPD_DIMMR programmed, which is
     typically if the DIMMs were integrated in the field.

FAQ:

1Q: What should I do if I find a 501-6109-03 or 501-7386-03 part numbers or
    501-6242 with SPD ver 1.14 in a Sun/Oracle system?
1A: Inform customers that these parts are not valid Sun/Oracle parts and report
    incident with all relevant details to [email protected] for
    further direction.

2Q: Will these memory DIMMs damage the Sun/Oracle systems?
2A: We are not aware of any damage to systems being caused by the use of these
    unapproved DIMMs.

3Q: Can I order FRU DIMMs to replace unapproved DIMMs?
3A: No, do not order Sun/Oracle DIMMs to replace these DIMMs. Ask the customer to
    work with the DIMM supplier to replace these DIMMs.  Do not attempt to contact
    the supplier yourself for any reason.

Note: If a customer insists on replacing the DIMMs through Sun/Oracle, send an email
      to the [email protected] alias to request further direction.

4Q: What should I do if I find I am being requested to install unapproved DIMMs
    into a system?
4A: Do not install the DIMMs. Inform customers that these parts are not valid
    Sun/Oracle parts and report incident, with all relevant details, to
    [email protected] for further direction.

5Q:  What should I do if I suspect other DIMMs not to be valid parts but are not
     listed is this document?
5A: You should send the details to [email protected] and someone
    from that team will get back to you.

Root Cause

Not applicable.

Corrective Action

Workaround

Not applicable.

Resolution

See FAQ above.

References:

  GSAP: 3228


For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL:

In addition to the above you may email:


Modification History
Changes made since initial publication.
Date: 21-Jul-2006
. Added GSAP number to document
Date: 11-Jun-2007
. Added second part number per [email protected]
Date: 18-Feb-2010<
. Updated FAB to remove greymarket weblink.

Previously Published As: 101868
Internal Contributor/submitter: unknown - originally submitted as PFIN
Internal Eng Business Unit Group: KE Authors
Internal Eng Responsible Engineer: [email protected]
Internal Services Knowledge Engineer: [email protected]

Internal Sun Alert and FAB Admin Info
Significant Change Date: 2006-05-16
Avoidance: None
Responsible Manager: unknown

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.