Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-73-1000171.1
Update Date:2012-08-20
Keywords:

Solution Type  FAB (standard) Sure

Solution  1000171.1 :   ECC/LRC pinned data may occur if cache blockades on SE9990/SE9985  


Related Items
  • Sun Storage 9990 System
  •  
  • Sun Storage 9985 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun FAB
  •  
  • .Old GCS Categories>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
200220


Product
Sun StorageTek 9990 System
Sun StorageTek 9985 System


Impact

When one side of cache is blocked due to a cache failure, ECC/LRC PIN data can occur. In the cache duplication process at the time of writing data to parity groups, a cache failure can occur, and an improperly duplicated extent will be specified due to a micro-program failure.

Contributing Factors
This issue can occur when both following conditions are met:
  • RAID1 parity groups exist in the subsystem
  • A cache failure blocks one side of cache
Affected MICRO-PROGRAM VERSIONS:

Microcode version equal to or greater than 50-04-48-00/00 can be affected by this issue.

Resolution

New release of microcode will provide a countermeasure to prevent the issue. The resolution for this issue is to install:
  • SE9990 (USP tagmaStore) MC 50-04-49-00/00 and above.
  • SE9985 (USP/NSC55) MC 50-05-23-00/00 and above.

Comments

Abbreviations used in this FIN.

ECC: Error correction code
LRC: Longitudinal Redundance Checksum
MC : Microcode
NSC: Network Storage Controller
USP: Universal Storage Platform

Related Information
  • Manual: SE99x0 Maintenance Manuals
  • URL: http://sejsc.ebay/AL/USP_045637R2.htm
    http://sejsc.ebay/AL/USP_045637_R500-PinnedData.pdf
    http://pts-storage.us.oracle.com/products/T99x0/documentation.html
    http://sccc-storage.emea:5071/cgi-bin/microcode/request.cgi
  • Other: Alert USP_045637

Previously Published As: 102199

Internal Contributor/submitter: [email protected]
Internal Eng Business Unit Group: KE Authors
Internal Eng Responsible Engineer: [email protected]
Internal Services Knowledge Engineer: [email protected]

Internal Kasp FAB Legacy ID: 102199

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date:
Avoidance: Service Procedure