Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X4370 M2 Server: Hardware Specifications

Processor
Number Two 6-Core CPU's per System Controller
Architecture Type: Intel Xeon 6-Core Processor
CPUs Intel 3.06 GHz 6-Core Xeon E5675 (12MB L2, 95W)
Main Memory
Capacities Total DIMM slots: 12 ( per System Controller)
DIMM type: DDR3 1333MHz Registered DIMMs
DIMM size: 8-GB 1333MHz, 1.35V
Maximum capacity: 96GB ( per System Controller)
Standard Integrated Interfaces
Network Two 10/100/1000 RJ-45 GbE Ethernet Ports on each System Controller
Network Management One dedicated 10/100 RJ-4 GbE port dedicated to the Service Processor (SP) on each System Controller
Serial Management One RS-232 RJ45 serial port on each System Controller
Video One rear panel high-density HD-15 video port on each system controller
System Controller Two system controllers (SCs) per chassis. Each SC operates independently from the other. The lower system controller is SC 0; the upper system controller is SC 1
USB Rear: Two USB 2.0 ports (for each system controller)
Internal: One USB 2.0 port (for each system controller)
PCI Expansion Slots Three external low profile PCI Express Gen-2 slots (x8) for each system controller. Each PCIe slot supports:
  • PCIe slot 2 - Dual-port SAS-2 host bus adapter (HBA) as part of the base configuration
  • PCIe slot 1 - Quad-port 1Gb Ethernet NIC
  • PCIe slot 0 - Dual-port 10Gb Ethernet NIC
  • One internal low profile PCI Express Gen-2 slot (x8). Dual-port SAS-2 HBA as part of the base configuration.
    Internal Mass Storage
    Disks SAS: Up to twenty 3.5" 600GB - 15000 RPM SAS HDDs in slots 0-19.
    SSD: Up to four 3.5" 73GB SAS Solid State Disks in slots 20-23.

    NOTE: The following storage configurations are supported for each System Controller:
  • Two rear accessed 2.5" 500GB - 7200 RPM SATA HDDs (reserved for operating system storage and system booting).
  • One internal 4 GB USB Memory Stick
  • Power Supplies
    Dual redundant, hot swappable power supplies
    (Power supply rating output = 1200W)
    (1100W @ 100-120 VAC; 1200W at 200-240 VAC, 50-60 Hz)
    (UL Maximum AC input = 1200W x 1.33 efficiency = 1596W)
    Service Processors
    Each System Controller has a Service Processor with the following features:
  • Includes the Baseboard Management Controller (BMC), which supports the IPMI feature set.
  • Supports KVMS over IP.
  • Includes a Serial port.
  • Supports Ethernet access to the Service Processor through a dedicated 10/100BaseT management port.
  • Environment
    Temperature Single, non-rack system:
    Operating: 5° C to 35° C (41° F to 95° F)
    Nonoperating: -40° C to 70° C (-40° F to 158° F)
    Humidity Single, non-rack system:
    Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
    Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
    Altitude Single, non-rack system:
    Operating: up to 3048 m (10,000 ft.), maximum ambient temperature is derated by 1° C per 300 m (984.25 ft) above 900 m (2,952.76 ft)
    Nonoperating: up to 12,000 m (39,370 ft.)
    Airflow 130 CFM typical; 250 CFM maximum.
    Regulations
    Meets or exceeds the following requirements:
    Safety UL 60950-1 2nd Ed, EN60950-1:2006 2nd Ed, CB Scheme with all country differences
    RFI/EMI FCC CFR 47 Part 15 Subpart B Class A, EN55022:2006+A1:2007 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
    Immunity EN55024, EN300-386
    Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
    EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
    Dimensions and Weight
    Height 175.1 mm (6.9 in.)
    Width (without mounting ears) 437 mm (17.2 in.)
    Width (with mounting ears) 482.6 mm (19 in.)
    Depth (to back of fan modules) 762 mm (30 in.)
    Depth (to fan module handles and latches) 782 mm (30.8 in.)
    Weight 72.6 kg (160 lb.)
    Rack Mounting
    Sun Fire X4370 M2 Server Racks Racks are as follows:
    • Four-post Racks are supported
    • Two-post Racks are not compatible

    • NOTES:
      Rack horizontal opening and unit vertical pitch must conform to ANSI/EIA 310-D-1992 or IEC 60927 standards.
      Distance between front and rear mounting planes must have a minimum 660.5 mm (26 in) and a maximum 876.3 mm (34.5").
      Distance to the front cabinet door must be at least 25.4 mm (1.0").
      Distance to the rear cabinet door must be at least 700 mm (27.5").
      Distance between structural supports and cable troughs must be at least 456 mm (18").

      Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.
     Feedback