Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Server X3-2L / Sun Fire X4270 M3 Server: Hardware Specifications

Processor
Number Two Quad-Core, 6-Core, or 8-Core
Architecture Type: Intel Xeon E5-2600 family
CPUs Intel 2.4GHz Quad-Core Xeon E5-2609 (10MB, 80W)
Intel 2.5GHz 6-Core Xeon E5-2640 (15MB, 95W)
Intel 2.2 GHz 8-Core Xeon E5-2660 (20MB, 95W)
Intel 2.9GHz 8-Core Xeon E5-2690 (20MB, 135W)
Cache L1: 32KB Instruction and 32KB data L1 cache per core
L2: 256KB shred data and instruction L2 cache per core
L3: Up to 20MB shared inclusive L3 cache per processor
Main Memory
Capacities Total DIMM slots: 16
DIMM type: DDR3 1600MHz Registered DIMMs
DIMM size: 8GB 1600MHz or16GB 1600MHz
Maximum capacity: 256GB (when configured with 16GB DIMMs)
Standard Integrated Interfaces
Network Supports Four 100/1000/10000 Base-T Ethernet Ports (100 at full-duplex only)
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: Two USB 2.0 ports
PCI Expansion Slots

Six low profile PCI Express 3.0 slots;
Slot 1: x16 electrical / x16 mechanical
Slots 2-6: x8 electrical

Internal Mass Storage
Disks 8-Disk configuration with DVD: 2.5in 300GB / 600GB SAS-2 or 100GB / 300GB SSD
12-Disk configuration:
3.5in 600GB SAS-2 or 3TB SAS (2 additional disks in the rear)
24-Disk configuration:
2.5in 300GB / 600GB SAS-2 or 100GB / 300GB SSD (2 additional disks in the rear)
Uses one of two supported internal HBAs for internal storage. The HBA is to be installed in PCI Express Slot 6.
Power Supplies
Dual redundant, hot swappable power supplies
(Maximum output power = 1000W)
Environment
Voltage 100 to 127 / 200 to 240 VAC
Input Current 12.0 A-8.5 A @ 100-127 V
5.7 A @ 200-240 V
AC power 50-60 Hz (47 to 63 Hz range)
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Maximum ambient operating temperature is derated by 1 degree C per 300 meters of elevation beyond 900 meters, up to a maximum altitude of 3,000 meters of elevation.)
Humidity Operating: 10% to 90% relative humidity noncondensing, short term -5 ° C to 55° C (25° F to 113° F)
Nonoperating: up to 93% relative humidity noncondensing, 37.7° C (100.4° F) max wet bulb
Altitude Operating: up to 3000 m (9,840 ft.) at 35° C (95° F)
Nonoperating: Maximum 12,000 m (39,370 ft)
Acoustic 7.61 Bels A weighted operating; 5.65 Bels A weighted idling
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, 2nd Edition, 2007-03-27 ; EN60950-1:2006 +A11:2009 +A1:2010 +A12:2011 ; IEC60950-1:2005 +A1:2009CB Scheme with all country deviations ; CNS14336-1 ; GB4943
EMI EN55022:2006 +A1:2007/CISPR22:2008 Class A ; 47 CFR 15B Class A ; ICES-003 Class A ; VCCI Class A ; AS/NZ 3548 Class A ; CNS 13438 Class A ; KSC 5858 Class A ; GB9254 Class A ; EN61000-3-2 ; GB17625.1 ; EN61000-3-3
Immunity EN55024:2010 ; IEC 61000-4-2 Electrostatic discharge ; IEC 61000-4-3 RF E-field immunity ; IEC 61000-4-4 Electrical Fast Transient/Burst ; IEC 61000-4-5 Surge ; IEC 61000-4-6 RF-Conducted immunity ; IEC 61000-4-8 Power frequency magnetic field immunity ; IEC 61000-4-11 Voltage dips, short interruptions
Ergonomics EK1-1TB-2000
Dimensions and Weight
Height 87.6 mm (3.5 in)
Width 445.0 mm (17.5 in)
Depth 737 mm (29 in)
Weight 31.8 kg (70 lbs) fully populated
Clearance and Service Access
Front
Rear
91 cm (36 in)
91 cm (36 in)
Rack Mounting
Sun Server X3-2L / Sun Fire X4170 M3 Server Racks Racks are as follows:
  • Sun Rack II 1042
  • Sun Rack II 1242

  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback