Processor
Number Up to two.
Architecture Type:Quad-core, Intel[tm] Xeon 5500 series processors with QuickPath Interconnect (QPI), Turbo Boost and Hyper-Threading (HT) technology.
  • Model/Speed/Watts: X5570, 2.93 GHz, 95W
  • Model/Speed/Watts: X5560, 2.80 GHz, 95W
  • Model/Speed/Watts: E5540, 2.53 GHz, 80W
  • Model/Speed/Watts: E5520, 2.26 GHz, 80W
  • Model/Speed/Watts: L5520, 2.26 GHz, 60W
Cache Memory 8 MB Cache
Main Memory
Memory Type DDR3-1066 DIMMs.
Capacities
  • Total DIMM slots: 18.
  • DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
  • DIMM sizes: 2 GB, 4 GB and 8 GB 1066MHz. 4GB 1333MHz.
  • Maximum capacity: 144 GB (when configured with 8-GB DIMMs).
Compact Flash
  • One on-board 16 GB Compact Flash option.
Optional Storage
Disk
  • Up to four optional, hot swappable, hot pluggable, drives per blade.
    Drive Type
    Density
    Speed
    Form Factor
    RAID
    SAS
    500 GB
    7,500 RPM
    2.5"
    Hardware RAID (requires REM)
    SAS
    300 GB
    10,000 RPM
    2.5"
    Hardware RAID (requires REM)
    SAS
    146 GB
    10,000 RPM
    2.5"
    Hardware RAID (requires REM)
    SAS
    73 GB
    15,000 RPM
    2.5"
    Hardware RAID (requires REM)
    SAS
    73 GB
    10,000 RPM
    2.5"
    Hardware RAID (requires REM)

    • Configuration rules are:
      1. SAS HDD, SATA HDD, SATA SSD can be mixed and matched, REM is required.
      2. Only SATA HDD, SATA SSD can be mixed and matched without a REM, REM is optional.
      3. If a SAS HDD is selected then a REM controller is required.
      4. Auto add HDD filler panel (part number 6331-N) based on empty HDD slots.
      5. SATA HDDs requires a quantity of 1 cable (part number 4859A) to be auto added when a REM is not selected.
      6. SATA HDDs requires a quantity of 1 cable (part number 4860A) to be auto added with a REM.
      7. SAS HDDs requires a quantity of 1 cable (part number 4860A) to be auto added with a REM.
      8. When SATA and SAS HDDs are mixed a quantity of 1 cable (part number 4860A) is required to be auto added with a REM.
      9. REM's - A REM is optional, but see Notes 1 an 3 above.
      10. Cannot mix SAS and SATA in the same volume.
Solid State Drives
  • 32 GB SATA solid state drive.
Sun Blade 6000 Disk Module Requires a RAID Expansion Module (REM) in the Sun Blade X6270. Also requires a Network Express Module (NEM) in the Sun Blade Modular System (6048 or 6000). The NEM has to have Sun Blade 6000 Disk Module support.
Management Environment
Sun Blade Server Module Service Processor (SP)
  • The SP is not a separate card. It is embedded on the motherboard.
  • The SP is installed with Integrated Lights-Out Manager (ILOM).
  • The SP provides one 10/100 Management Ethernet Port to Midplane and the Chassis Monitoring Module (CMM).
  • ILOM on the SP card can be accessed via the Dongle cable assembly.
    • Both the three-cable (X4622A) and four-cable (X4621A) dongle cable options can be used to connect to ILOM using the Universal Connector Port (UCP) on the front of the Sun Blade X6270.
    • Use the DB-9 serial connector with the DB9F to RJ45F adapter on the 4-cable dongle to connect to ILOM via the UCP.
    • Use the RJ-45 serial connector on the 3-cable dongle to connect to ILOM via the UCP.
  • The SP card and LOM provide the following:
    • Remote management with full Keyboard, Mouse, Video, Storage (KVMS) redirection.
    • Remove media capability (floppy, DVD, CD etc.).
    • DMTF style CLI.
    • Browser-based UI for control of the system through a graphical interface.
    • IPMI 2.0 compliance for management and control.
    • SNMP V1, V2c, V3 for system monitoring.
    • Monitor and report system and component status on all FRUs.
Standard Integrated Interfaces
Universal Connector Port (UCP) The Dongle Cable assembly connects to the UCP and provides the following:
  • Connection to ILOM SP.
  • 2 USB 2.0 ports.
  • VGA video connection to an on-board AST2100 graphics chip.
Network Management Two 10/100Base-T Ethernet connection via midplane to the CMM. Only one connection (NET 0) is used.
Ethernet Two 10/100/1000Base-T Ethernet ports routed through midplane to 2 NEM slots.
PCI Interfaces with the Sun Blade Modular System (chassis)
  • I/O is offered in two form factors:
    • PCI Express ExpressModules (EM)
      and
    • PCI Express Network Express Modules (NEM).
  • Each Sun Blade X6270 has four, PCI Express Gen 2 links allocated to:
    • Two EMs (X8)
      and
    • Two NEMs (X4).
  • Each NEM has one link assigned to each server module. All server modules share the NEM. For example, Blade 0 has access to NEM 0/slot 0, and NEM 1/slot 0. Blade 1 to NEM 0/slot 1 and NEM 1/slot 1, etc.
  • EM slots are not shared between server modules. Each EM slot is specific to one server module.
Regulations
RoHS Compliance Level RoHS:YL
Dimensions and Weights
Height 44mm (1.7 in).
Width 327mm (12.87 in).
Depth 512mm (20.16 in).
Weight (with 4 disks, 1 FEM, 1 REM, 2 processors) 7.9 kg (17.4 lbs).

  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.