Processor |
Number |
Two or Four SPARC T4 8-Core 3.0GHz processors |
Architecture |
SPARC V9 architecture |
CPUs |
- 3.0GHz 8-Core
- 256 threads max
- Eight floating-point units per processor,
one per core
- 10 Gigabit Ethernet integrated into chip
- On-board cryptography with direct non-privileged support for 16 industry-standard cryptographic algorithms plus random number generation in each of the eight cores:
AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC, Kasumi, MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512
|
Cache memory |
4MB integrated L3 with a private L2 128K cache |
Main Memory |
Capacities |
- Total DIMM slots:
64
- DIMM type: DDR3
- DIMM size:
4GB, 8GB, and 16GB
- Minimum Configuation: 64GB (16 × 4GB)
- Maximum capacity:
1,024 (64 × 16GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10/100/1000 Mbps autonegotiating ports
Up to 8 × optional 10 GbE XAUI connections |
Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port
Note: This port does not support connections to Gigabit networks. |
Serial Management |
One dedicated RJ-45 port
An additional serial mangemant port is located on the main module and is
accessible from the front panel. |
Remote Management |
Onboard system processor, running Integrated Lights
Out Manager (ILOM) 3.0 |
Graphics |
One DB-15 VGA connector |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports |
PCI Expansion Slots |
16 PCI-Express Gen2 slots
|
Internal Mass Storage |
Disks |
- Up to eight 2.5-inch
SAS drives
- 300GB and 600GB 2.5-inch SAS disk drives
- RAID 0 and RAID 1 support
|
Power Supplies |
4 × 2060 Watt, hot-swappable, 2+2
redundant power supply units (PSU) |
Environment |
Input Voltage |
200 - 240 VAC, 50-60Hz (VAC tolerance +/- 10%) |
Input Current |
14.6 A @ 200 VAC max |
Input Power |
2770 W @ 200 VAC
max |
Heat Output |
9554 BTU/hour or 10080 KJ/hour |
Temperature |
Operating:
5° C to 35° C (41° F to 95° F)
Nonoperating:
-40° C to 65° C (-40° F to 149° F)
Note: Above 900m (3000 ft), decrease maximum
temperature as altitude increase, 1° C/300m (1.6° F/1000ft)
|
Humidity |
Operating:
10% to 90% relative humidity noncondensing, 27° C (80.6° F) maximum
wet bulb
Nonoperating: 93% relative humidity noncondensing, 38° C (100.4°
F) maximum wet bulb |
Altitude |
Operating:
0m to 3000m (10000 ft.)
Nonoperating: 0m to 12000m (40000 ft.) |
Vibration |
Operating: 0.15G (x-axis), 0.10G (x,y axes)
5-500Hz swept sine
Nonoperating: 0.5G (x-axis), 0.25G (x,y axes) 5-500Hz swept sine |
Shock |
Operating: 3Gs, 11ms half-sine
Nonoperating: 1-inch roll-off free fall, front-to-back rolling direction,
25mm threshold height at 0.75 m/s impact velocity |
Acoustic Noise |
Operating/Idling:
8.2 B (LwAd, 1B = 10dB)
Operating/Idling: 68.2dB (LpAm, bystander positions) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1, EN 60950-1, IEC 60950-1 CB Scheme with all country deviations, IEC 825-1, 2 CFR 21 part 1040, CNS 14336 |
EMI/EMC |
EN 55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, EN 61000-3-2, EN 61000-3-3
|
Immunity |
EN 55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
|
Regulatory Markings |
CE, FCC, ICES-003, C-Tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-Mark
|
European Union Directives |
2006/95/EC (73/23/EEC) Low Voltage Directive, 2004/108/EC (89/336/EEC) EMC Directive, 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) Directive, 2002/95/EC Restriction of Hazardous Substances (RoHS) Directive
|
Dimensions and Weight |
Height |
219 mm (8.62 in.) |
Width |
445 mm (17.5 in.) |
Depth |
700 mm (27.65 in.) |
Weight |
Appx 79 kg (175 lbs) max |
Clearance
and Service Access |
Front |
910 mm (36 in.) |
Rear |
910 mm (36 in.) |