SPARC[tm] T4-2 Server: Hardware Specifications

Processor
Number Two SPARC T4 8-Core 2.85GHz processors
Architecture SPARC V9 architecture, ECC Protected
CPUs
  • 2.85GHz 8-Core
  • 64 threads per CPU, 128 threads max
  • Eight floating-point units
  • Dual multithreaded 10 GbE PCI integrated onto each chip
  • On-chip Encryption Instruction Accelerators with direct non-privileged support for
    16 industry-standard cryptographic algorithms plus random number generation in
    each of the eight cores: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC,
    Kasumi, MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512
Cache memory Shared L3, 4MB cache and eight cores with private L2 128K cache
Main Memory
Capacities
  • Total DIMM slots: 32 - 8 slots per memory riser, 2 memory risers per CPU
  • DIMM type: DDR3
  • DIMM size: 4GB, 8GB, or 16GB
  • Minimum Configuation: 64GB. (16 × 4GB). 16 slots is minimum slot configuration.
  • Maximum capacity: 512GB (32 × 16GB)
Standard Integrated Interfaces
Network 4 × 10/100/1000 Mbps autonegotiating ports
Network Management One dedicated 10/100Base-T RJ-45 port Ethernet port
Serial Management One dedicated RJ-45 port
Remote Management Onboard service processor, running Integrated Lights Out Manager (ILOM)
Graphics Two DB-15 VGA connectors (one front, one rear)
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
PCI Expansion Slots
  • 10 low-profile PCI-Express 2.0 slots.
  • 1 Network Module Card slot (only for 10Gb Network Module card, does not support standard PCI-Express cards)
Slot # Physical Electrical
0 x8 x8
1 x8 x8
2 x8 x8
3 x16 x8
4 x8 x4
5 x8 x4
6 x16 x8
7 x8 x8
8 x8 x8
9 x8 x8
Internal Mass Storage
Disks
  • Up to six 2.5-inch SAS drives
  • 300GB & 600GB 2.5-inch SAS disk drives
  • RAID 0, RAID 1, and RAID 1E support
DVD-ROM 1 slimline SATA DVD +/-RW
Power Supplies
2 × 2060 Watt, hot-swappable, N+1 redundant power supply units (PSU)
Environment
Input Voltage 200 - 240 VAC, 50-60Hz
Input Current 7.6A @ 200 VAC
Maximum Heat Dissipation 4,953 BTU/hr, 5226 KJ/hr
Power Consumption Online power calculator
Temperature

Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)

Humidity Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) maximum wet bulb
Nonoperating: Up to 93% relative humidity noncondensing, 38° C (100.4° F) maximum wet bulb
Altitude

Operating: Up to 3048m (10000 ft), maximum ambient temperature is derated by 2° C for every 1km (3.6° F for every 3280ft)
Nonoperating: Up to 12000m (40000 ft.)

Vibration Operating: 0.15G (vertical), 0.10G (horizontal) 5-500Hz swept sine
Nonoperating: 0.5G (vetical), 0.25G horizontal) 5-500Hz swept sine
Shock Operating: 3Gs, 11ms half-sine
Nonoperating:
Roll-off: 1-inch roll-off free fall, front-to-back rolling direction
Threshold: 25mm threshold height at 0.75 m/s impact velocity
Acoustic Noise Operating/Idling:61.5 dB / 61.2 dB (LwAd, 1B = 10dB)
Operating/Idling: 7.7 B / 7.6 B (LpAm, bystander positions)
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA 60950-1, EN 60950-1, IEC 60950-1 CB Scheme with all country
deviations, IEC 825-1, 2 CFR 21 part 1040, CNS 14336
EMI/EMC EN 55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A,
AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, EN 61000-3-2, EN
61000-3-3
Immunity EN 55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Regulatory Markings CE, FCC, ICES-003, C-Tick, VCCI, GOST-R, BSMI, MIC,
UL/cUL, UL/S-Mark
Dimensions and Weight
Height 129.85 mm (5.11 in.)
Width 436.5 mm (17.18 in.)
Depth 732 mm (28.81 in.)
Weight Max: 36.29 kg (80 lbs), without rackmount kit
Clearance and Service Access
Front 910 mm (36 in.)
Rear 910 mm (36 in.)